Dear Customer,

Our compliments for having chosen a top-quality Immergas product, able to assure well-being and safety for a long period of time.

 

As an Immergas customer 

you can also count on a qualified after-sales service, prepared and updated to guarantee constant efficiency of your storage tank unit.
Read the following pages carefully: you will be able to draw useful suggestions regarding the correct use of the appliance, the respect of which, will confirm 

your satisfaction for the Immergas product.
For assistance and scheduled maintenance contact Authorised After-Sales centres: they have original spare parts and are specifically trained directly by the 

manufacturer. 

General recommendations

All Immergas products are protected with suitable transport packaging. 
The material must be stored in dry environments protected against bad weather.
The instruction book is an integral and essential part of the product and must be consigned to the new user also in the case of transfer or succession of ownership.
It must be stored with care and consulted carefully, as all of the warnings provide important safety indications for installation, use and maintenance stages.
This instructions manual provides technical information regarding installation of Immergas storage tank units. As for the other issues related to installation 

of the said storage tank units (e.g. safety in the work site, environment protection, injury prevention), it is necessary to comply with the provisions specified in 

the regulations in force and principles of good practice.
In compliance with legislation in force, the systems must be designed by qualified professionals, within the dimensional limits established by the Law. Installation 

and maintenance must be performed in compliance with the regulations in force, according to the manufacturer's instructions and by an authorised company, 

which has specific technical expertise in the system sector, as required by Law.
Improper installation or assembly of the Immergas appliance and/or components, accessories, kit and devices can cause unexpected problems to people, animals 

and objects. Read the instructions provided with the product carefully to ensure a proper installation.
Maintenance must be carried out by an authorised company. The Authorised After-sales Service represents a guarantee of qualification and professionalism.
The appliance must only be destined for the use for which it has been expressly declared. Any other use will be considered improper and therefore potentially 

dangerous. 
If errors occur during installation, operation and maintenance, due to non compliance with technical laws in force, standards or instructions contained in this 

book (or however supplied by the manufacturer), the manufacturer is excluded from any contractual and extra-contractual liability for any damages and the 

appliance warranty is invalidated. 
For further information regarding legislative and statutory provisions relative to the installation of gas heat generators, consult the Immergas site at the 

following address: www.immergas.com

Immergas S.p.A. declines all liability due to printing or transcription errors, reserving the right to make any modifications to its technical and commercial 

documents without prior notice.

Mauro Guareschi

Research & Development Director

Signature:

CE DECLARATION OF CONFORMITY

 (according to ISO/IEC 17050-1)

The company 

IMMERGAS S.p.A.

, with registered office in via Cisa Ligure 95 42041 Brescello (RE) whose design, manufacturing, and after sale assistance 

processes comply with the requirements of standard 

UNI EN ISO 9001:2008

,

DECLARES that:

The UB INOX SOLAR 200 ERP storage tank units comply with the following European Directives and Delegated European Regulations: 

“Eco-design” Directive 2009/125/EC, “Energy labelling” Directive 2010/30/EC, EU Regulation 812/2013, EU Regulation 814/2013, “Electromagnetic 

Compatibility” Directive 2004/108/EC and “Low Voltage” Directive 2006/95/EC.

Содержание UB INOX SOLAR 200 ERP

Страница 1: ...UB INOX SOLAR 200 ERP Storage tank unit IE Instruction and recommendation booklet 1 038280ENG ...

Страница 2: ......

Страница 3: ...which has specific technical expertise in the system sector as required by Law Improper installation or assembly of the Immergas appliance and or components accessories kit and devices can cause unexpected problems to people animals and objects Read the instructions provided with the product carefully to ensure a proper installation Maintenance must be carried out by an authorised company The Auth...

Страница 4: ... pump solar heating system 8 1 12 Commissioning 9 1 13 Filling the solar circuit system 9 1 14 Solar control unit user instructions 10 1 15 Main components 13 1 16 Kits available on request 13 2 Use and maintenance instructions 14 2 1 Cleaning and maintenance 14 2 2 Emptying the storage tank unit 14 2 3 Cleaning the case 14 2 4 Decommissioning 14 2 5 Control panel 14 3 Checks and maintenance 15 3 ...

Страница 5: ...t operation turn the appliance off and contact an authorised company e g the Authorised Tech nical Assistance centre which has specifically trained staff and original spare parts Do not attempt to modify or repair the appliance alone Failuretocomplywiththeaboveimpliespersonal responsibility and invalidates the warranty Installation standards these storage tanks have been designed for floor install...

Страница 6: ... tank unit Attention after the connections have bee made the new system layout must be set on the solar control unit as follows press the i key for about 10 seconds use the scrolling keys to find parameter 27 system configuration press the i key for about 2 seconds upon accessing parameter 27 you will find that configuration 1 is set use the scrolling keys to select configuration 2 press the i key...

Страница 7: ...efer to the boiler instruction book 1 10 MAIN SOLAR CIRCULATION UNIT COMPONENTS The pump unit allows you to connect the storage tank to the solar manifold making the water cir culateaccordingtotherequestofthecontrolunit Hydraulic circuit resistance Head kPa Flow rate l h Head m c a A Storage tank unit hydraulic circuit resistance Key 1 Solar pump 2 Non return valve thermometer and cock 3 Valve dra...

Страница 8: ...ontrol to set advanced functions For proper op eration one must select the most suitable type of operation for the system and select a speed in the available range with a focus on energy savings Display of operation status During normal operation the status LED 2 is on green flashing FL when it is in stand by the four yellow LEDs 3 indicate circulator absorption according to the following table Ci...

Страница 9: ... the roof at a hypothetical height of 6 m the distance to be calculated is 6 m x 0 1 bar 0 6 bar therefore the expansion vessel must be charged to 2 0 6 2 6 bar Hydraulic unit safety valve There is a safety valve present on the hydraulic unit that protects the system from an excessive increase in pressure This valve intervenes by discharging the liquid contained in the circuit when the pressure re...

Страница 10: ...Otherwise press to exit In this case the value set will not be memorised but the previ ous one will be kept To exit the parameter menu press the button once or wait 60 seconds without press ing any keys 6 Eliminate any air in the solar circuit preferably using the so called pressure shot method which consists in raising the filling pressure of the circuit followed by a quick opening of the return ...

Страница 11: ...re C 90 160 C 140 C 18 Tank Maximum Temperature C 70 95 C 80 C 19 Value of the temperature differential between the solar collector maximum temperature PAR 17 and the solar collector temperature above which the solar collector cooling func tion activates Solar collector cooling function 0 Function deactivated 0 20 C 0 20 Diverter functioning 0 Off 1 Auto 2 On 0 2 1 21 Value of the Δ flow return te...

Страница 12: ...ly with return probe when Solar collector T solar collector return T PAR 21 Solar manifold anti freeze function The Solar Pump activates when Solar collector T PAR 23 The board will not deactivate the solar pump until Solar collector T PAR 23 1 C Attention the default anti freeze function is disabled PAR 23 0 Solar pump anti block function After 24 hours of inactivity the system pumps are activate...

Страница 13: ...s 16 Solar panel probe 17 Storage tank electric connections terminal board 1 16 KITS AVAILABLE ON REQUEST Recirculation kit on request The storage tank unit is prepared for application of the pump kit Immergas supplies a series of fittings and attachments that allow connection between the storage tank unit and domestic hot water system The pump kit attachment is also envi sioned on the template El...

Страница 14: ...horised local firm 2 2 EMPTYING THE STORAGE TANK UNIT To drain the storage tank use the special drain ing valve in the lower part of the storage tank Fig 1 12 part 8 Before draining ensure that the DHW inlet valve is closed 2 3 CLEANING THE CASE Use damp cloths and neutral detergent to clean the storage tank casing Never use abrasive or powder detergents 2 5 CONTROL PANEL Key 1 Solar control unit ...

Страница 15: ...filter 11 One way valve OV 15 Optional 12 Cold water inlet cock 13 One way solar valve 14 6 bar safety valve 15 Shut off valve with thermometer 16 Solar expansion vessel 17 Solar pump 18 Flow meter 19 Domestic hot water probe 20 Domestic hot water unabling probe 21 Stainless steel coil that can be coupled to solar panels 22 Solar system draining valve 23 Solar panel probe AC Domestic hot water out...

Страница 16: ...r the DHW regulation NTC probe Check the integrity of the storage tank Magne sium anode Check the state of the internal coil Check for any slurry deposits on the bottom of the storage tank Key A12 Solar management control unit B2 Domestic hot water probe NTC B11 Solar manifold probe PT1000 B12 Solar storage tank probe NTC B19 DHW inhibition probe NTC B20 Solar manifold return probe PT1000 Optional...

Страница 17: ...t models remove the lid 1 by pulling it upwards undo the screws 2 and pull the front panel outwards 3 undo the screws 4 of the sides 5 on the top and in the lower part of the sides themselves After having released them from the screws they can be removed by pulling them forward and then upwards 3 5 REPLACING THE ANODE Themagnesiumanodemustbereplacedannually Fig 1 12 part 5 present in the storage t...

Страница 18: ... l h 1140 1140 Coil head loss at 1000 l h kPa m H2 O 12 3 1 25 Central heating side maximum pressure bar 6 Central heating side maximum temperature C 90 Solar heat exchange maximum output kW 23 8 CH heat exchange maximum output kW 26 5 Full weight kg 310 67 Empty weight kg 106 1 Total water content l 204 57 Solar circuit maximum pressure bar 6 Total volume solar expansion vessel l 18 Solar expansi...

Страница 19: ...19 A B C D E F G 143W 200L F UB INOX SOLAR 200 ERP 3 7 PRODUCT SHEET IN COMPLIANCE WITH REGULATION 812 2013 ...

Страница 20: ...5 Inglese per IRLANDA IE Followus Immergas Italia immergas com Immergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 ИЗКЛЮЧИТЕЛЕН ПРЕДСТАВИТЕЛ И СЕРВИЗ АМАКС ГАЗ ООД 1261 Мрамор София ул В Левски 148 Tel 0700 112 66 Fax 02 902 46 70 www amaxgas com ...