35
STMaE4E and 07/11
MAIOR EOLO 4 E
Technical Documentation
Technical Documentation
Id
Parameter
(ref. 17)
Parameter
Description
Range
(ref. 21)
Default
P0
DHW
thermostat
Establishes the switch-off method in DHW mode.
0 Correlated: the boiler switches off on the basis of the temperature set.
1 Fixed: the switch-off temperature is fixed on the maximum value independently
from the value set on the control panel.
0 - 1
1
P1
Solar delay
timing
The boiler is set to switch-on immediately after a request. for DHW In the case
of coupling with a solar storage tank positioned upstream from the boiler, it is
possible to compensate the distance between the storage tank and the boiler in
order to allow the water to reach the boiler. Set the time necessary to verify that
the water is hot enough (see par. Solar panels coupling)
0 - 30
seconds
0
P2
Pump
functioning
0 Intermittent: In winter "mode" the pump is managed by the room thermostat
or by the remote control
1 Continuous: In "winter" mode the pump is always powered and so functions
continuously
0 - 1
0
P3
Relay 1
(optional)
The boiler is set-up for functioning with the relay P.C.B. (optional), which can
be configured
0
= Off
1
= Main zone control
2
=General alarm
3
= CH phase active
4
= External gas valve power supply
5
= PTC Aqua Celeris control
0 - 5
5
P4
Relay 2
(optional)
The boiler is set-up for functioning with the relay P.C.B. (optional), which can
be configured
0
= Off
1
=General alarm
2
= CH phase active
3
= External gas valve power supply
4
= Secondary zone control (from TA on relay P.C.B. contact)
0 - 4
0
P5
Relay 3
(optional)
The boiler is set-up for functioning with the relay P.C.B. (optional), which can
be configured
0
= Off
1
= Chiller remote activation
2
=General alarm
3
= CH phase active
4
= External gas valve power supply
5
= PTC Aqua Celeris control
0 - 5
0
Menu "P"