50
STMaE4E and 07/11
MAIOR EOLO 4 E
Technical Documentation
Technical Documentation
F
The flow (flow rate) of the DHW is at least 1.5 l/min.
No
On the DHW system, check the correct opening of any cocks, cleanliness
of the pipes, filters, flow rate limiters etc.
Yes
The flow switch functions correctly.
No
Check/clean/replace the flow switch.
Yes
The wiring between the flow switch and the board is OK.
No
Restore the electric connection/replace the wiring.
Yes
Replace the P.C.B.