31
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
Combustion parameters: measuring conditions
of useful efficiency (flow temperature/return
temperature= 80 / 60 °C), ambient temperature
reference = 15°C.
G20
G30
G31
Eolo Mythos Dom 10 1E
Gas nozzle diameter
mm
1.30
0.79
0.79
supply pressure
mbar (mm H
2
O)
20 (204)
29 (296)
37 (377)
Flue flow rate at nominal heat output
kg/h
55
52
54
Flue flow rate at min heat output
kg/h
57
57
54
CO
2
at Nom./Min. Q.
%
6.63 / 2.06
8.00 / 2.40
7.73 / 2.50
CO with 0% O
2
at Nom./Min. Q.
ppm
88 / 148
158 / 228
94 / 187
NO
X
with 0% O
2
at Nom./Min. Q.
mg/kWh
89 / 51
138 / 37
128 / 39
Flue temperature at nominal output
°C
101
108
108
Flue temperature at minimum output
°C
97
105
102
Maximum intake / exhaust available head with concentric flue
Pa
74
Intake / exhaust available head with divided flue
max. exhaust length 27 metres or intake length 33 metres
(intake diaphragm Ø 45)
Pa
81
Intake / exhaust available head with divided flue
max. intake length from 33 to 40 metres
(intake diaphragm Ø 45 and exhaust blade 15)
Pa
110
Eolo Mythos Dom 18 1E
Gas nozzle diameter
mm
1.30
0.79
0.79
supply pressure
mbar (mm H
2
O)
20 (204)
29 (296)
37 (377)
Flue flow rate at nominal heat output
kg/h
55
52
54
Flue flow rate at min heat output
kg/h
57
57
54
CO
2
at Nom./Min. Q.
%
6.63 / 2.06
8.01 / 2.40
7.73 / 2.50
CO with 0% O
2
at Nom./Min. Q.
ppm
88 / 148
158 / 228
94 / 187
NO
X
with 0% O
2
at Nom./Min. Q.
mg/kWh
89 / 51
138 / 37
128 / 39
Flue temperature at nominal output
°C
119
128
124
Flue temperature at minimum output
°C
97
105
102
Maximum intake / exhaust available head with concentric flue
Pa
74
Intake / exhaust available head with divided flue
max. exhaust length 27 metres or intake length 33 metres
(intake diaphragm Ø 45)
Pa
81
Intake / exhaust available head with divided flue
max. intake length from 33 to 40 metres
(intake diaphragm Ø 45 and exhaust blade 15)
Pa
110
Eolo Mythos Dom 24 1E
Gas nozzle diameter
mm
1.30
0.79
0.79
supply pressure
mbar (mm H
2
O)
20 (204)
29 (296)
37 (377)
Flue flow rate at nominal heat output
kg/h
55
52
54
Flue flow rate at min heat output
kg/h
57
57
54
CO
2
at Nom./Min. Q.
%
6.63 / 2.06
8.01 / 2.40
7.73 / 2.50
CO with 0% O
2
at Nom./Min. Q.
ppm
88 / 148
158 / 228
94 / 187
NO
X
with 0% O
2
at Nom./Min. Q.
mg/kWh
89 / 51
138 / 37
128 / 39
Flue temperature at nominal output
°C
127
134
131
Flue temperature at minimum output
°C
97
105
102
Maximum intake / exhaust available head with concentric flue
Pa
74
Intake / exhaust available head with divided flue
max. exhaust length 27 metres or intake length 33 metres
(intake diaphragm Ø 45)
Pa
81
Intake / exhaust available head with divided flue
max. intake length from 33 to 40 metres
(intake diaphragm Ø 45 and exhaust blade 15)
Pa
110
3.17 COMBUSTION PARAMETERS.
Содержание EOLO MYTHOS DOM 10 1E
Страница 1: ...EOLO MYTHOS DOM 10 18 24 1E Instructions and warning book 1 041321ENG ...
Страница 2: ......
Страница 34: ...34 ...
Страница 35: ...35 ...