65
MAGIS HERCULES PRO 12-14-16
MAGIS HERCULES PRO
12
Water flow temperature °C
25
30
35
Air temperature °C
d.b. (w.b.)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
-20
(-21)
9.67
3.19
9.40
3.42
8.95
3.84
-15
(-16)
11.01
3.37
10.71
3.61
10.20
4.06
-10
(-11)
12.70
3.55
12.35
3.81
11.76
4.28
-7
(-8)
12.20
3.40
11.87
3.65
11.30
4.10
-2
(-3)
12.04
3.01
11.71
3.23
11.15
3.63
2
(1)
11.88
2.62
11.55
2.81
11.00
3.16
7
(6)
12.96
2.15
12.60
2.31
12.00
2.59
10
(9)
14.16
2.17
13.76
2.33
13.11
2.61
15
(14)
16.15
2.20
15.70
2.36
14.95
2.65
20
(19)
18.14
2.23
17.64
2.39
16.80
2.69
31
“POWER” AND “ABSORPTION” IN CENTRAL HEATING MODE
MAGIS HERCULES PRO 12
MAGIS HERCULES PRO
12
Water flow temperature °C
40
45
50
Air temperature °C
d.b. (w.b.)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
-20
(-21)
8.61
4.10
8.26
4.52
-15
(-16)
9.91
4.31
9.62
4.57
9.33
4.79
-10
(-11)
11.41
4.51
11.05
4.75
10.72
4.98
-7
(-8)
11.06
4.63
10.82
5.15
10.38
5.22
-2
(-3)
10.72
3.98
10.30
4.34
9.78
4.88
2
(1)
10.39
3.34
9.78
3.52
9.29
3.97
7
(6)
11.75
2.91
11.50
3.23
11.26
3.53
10
(9)
12.86
2.94
12.61
3.27
11.98
3.68
15
(14)
14.71
2.95
14.47
3.35
13.74
3.77
20
(19)
16.56
3.02
16.32
3.42
15.50
3.85
MAGIS HERCULES PRO
12
Water flow temperature °C
55
Air temperature °C
d.b. (w.b.)
Max. output
(kW)
Max. absorbed
(kW)
-20
(-21)
-15
(-16)
-10
(-11)
9.95
5.46
-7
(-8)
9.95
5.30
-2
(-3)
9.27
5.42
2
(1)
8.80
4.41
7
(6)
11.01
3.83
10
(9)
11.35
4.09
15
(14)
13.02
4.18
20
(19)
14.69
4.28
- Correction factor stated DC = 0.9
- TOL = -25 °C