27
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
1st
Level
Button
2nd Level
Button
3rd Level
Button
Description
M1
D
C
P11
D
C
View the management software version of the P.C.B. installed in the
boiler
P12
View the total functioning hours of the boiler
P13
View the number of burner ignitions
P14
(with optional
external probe
present)
- - -
(without external
probe (optional)
D
C
P14/A
View the current external temperature (if optional external probe
present)
P14/B
View the minimum external temperature recorded (if optional exter-
nal probe present)
P14/C
View the maximum external temperature recorded (if optional exter-
nal probe present)
RESET
D
x
select
C
By pressing button “D” the MIN and MAX temperatures are brought
to the default value of 25 °C
P15
D
C
No display on this boiler model
P17
View the speed in instantaneous revs.of the fan
P18
The value displayed does not affect this model
P19
View the last 5 events that caused boiler shutdown. Indicator (6)
shows the sequential number from 1 to 5 and on indicator (7) the
relative error code.
By pressing button "D" repeatedly it is possible to view the function-
ing time and the number of ignitions at which the anomaly occurred
1st Level Button
2nd Level
Button
3rd Level
Button
4th Level
Button
Description
M3
D
C
P31
D
C
AUTO
(Default)
D
x
select
C
The display lights up when the burner
is ignited and when the controls are ac-
cessed, it remains on for 5 seconds after
the last operation performed
ON
The display is always lit up
OFF
The display only lights up when the
controls are accessed and remains on for 5
seconds after the last operation performed
P32
D
C
P32/B
D
C
ITALIANO
D
x
select
C
All descriptions are given in Italian
A1
(Default)
All descriptions are given in alphanumeri-
cal format
P33
D
C
OFF
(Default)
D
x
select
C
In winter mode, by activating this func-
tion, it is possible to activate the domestic
hot water function even if the eventual
remote zone control is out of service.
ON
RESET
D
x
select
C
By pressing button “D” the customisations
are reset, restoring the default values of
“P31” in “ILL. AUTO” and “P32/B” in
“ITALIAN” set by default.
Customisations Menu “M3”.
This menu contains
all functioning options that can be customised.
(The first item of the various options that appears
inside the parameter is that selected by default).
Attention:
if the international language is to be
restored
(A1)
, proceed as follows:
- press button "D" to access the configuration
menu.
- turn selector switch "3" to
“PERSONAL”
.
- press button "D" to confirm.
- turn selector switch "3" to
“DATI”
.
- press button "D" to confirm.
- turn selector switch "3" to
“LANGUAGE”
.
- press button "D" to confirm.
- turn selector switch "3" to
“A1”
.
- press button "D" to confirm.
At this point the international items indicated in
the menu tables appear on the display.
2.7 BOILER PARAMETERS AND
INFORMATION MENU.
By pressing the button "D" it is possible to access
a menu divided into three main parts:
- “M1” information
- “M3” customisations
- “M5” configurations: menu reserved to the
technician and for which a password is required
(See “Maintenance” chapter).
By turning the central heating temperature se-
lector switch (3) scroll through the menu items.
By pressing button “D” access the various levels
of the menu and the choice of parameters is
confirmed. Press button “C” to go back one level.
“M1” information menu.
This menu contains the various information relative to boiler functioning: