Hydraulic connection.
Attention:
in order not to void the condensation
module warranty, before making the boiler
connections, carefully wash the heating system
(pipes, radiators, etc.) with special pickling or
descaling products to remove any deposits that
could compromise correct boiler operation.
A chemical treatment of the thermal system
water is required, in compliance with the
technical standards in force, in order to protect
the system and the appliance from deposits (e.g.,
limescale), slurry or other hazardous deposits.
Water connections must be made in a rational
way using the couplings on the boiler template.
The boiler safety valve outlet must be connected
to a draining funnel. Otherwise, the manufacturer
declines any responsibility in case of flooding if
the drain valve cuts in.
Attention:
to preserve the duration of appliance
efficiency features, in the presence of water whose
features can lead to the deposit of lime scale,
installation of the “polyphosphate dispenser” kit
is recommended .
Electrical connection:
The Nike Mini 28 kW
Special boiler has an IPX4D protection rating
for the entire appliance. Electrical safety of the
appliance is reached only when it is correctly
connected to an efficient earthing system as
specified by current safety standards.
Attention:
the manufacturer declines any
responsibility for damage or physical injury
caused by failure to connect the boiler to an
efficient earth system or failure to comply with
the reference standards.
Also ensure that the electrical installation
corresponds to maximum absorbed power
specifications as shown on the boiler data-plate.
Boilers are supplied complete with an “X” type
power cable without plug. The power supply
cable must be connected to a 230V ±10% / 50Hz
mains supply respecting L-N polarity and earth
connection;
, this network must also have a
multi-pole circuit breaker with class III over-
voltage category. When replacing the power
supply cable, contact a qualified technician (e.g.
the Immergas After-Sales Technical Assistance
Service). The power cable must be laid as shown
(Fig. 1-3). In the event of mains fuse replacement
on the P.C.B., use a 2A quick-blow fuse. For the
main power supply to the appliance, never use
adapters, multiple sockets or extension leads.
1.4 REMOTE CONTROLS AND
ROOM CHRONO-THERMOSTATS
(OPTIONAL).
The boiler is prepared for the application of room
chrono-thermostats or remote controls, which
are available as optional kits. (Fig. 1-4)
All Immergas chrono-thermostats are connected
with 2 wires only. Carefully read the user and
assembly instructions contained in the accessory
kit.
• On/Off digital chrono-thermostat. The chrono-
thermostat allows:
- set two room temperature value: one for
daytime (comfort temperature) and one for
nighttime (lower temperature);
- set a weekly programme with four daily
switch on and switch off times;
- select the required operating mode from the
various possible alternatives:
- manual mode (with adjustable temperature).
- automatic mode (with set programme).
- forced automatic mode (momentarily
changing the temperature of the automatic
programme).
The chrono-thermostat is powered by two 1.5V
LR 6 type alkaline batteries;
• Comando Amico Remoto Remote Control
Device
V2
(CAR
V2
) with climate chrono-
thermostat function. In addition to the
functions described in the previous point, the
CAR
V2
panel enables the user to control all the
important information regarding operation
of the appliance and the heating system with
the opportunity to easily intervene on the
previously set parameters, without having
to go to where the appliance is installed.
The panel is provided with self-diagnosis to
display any boiler functioning anomalies.
The climate chrono-thermostat incorporated
into the remote panel enables the system flow
temperature to be adjusted to the actual needs
of the room being heated, in order to obtain
the desired room temperature with extreme
precision and therefore with evident saving in
running costs. The chrono-thermostat is fed
directly by the boiler by means of the same 2
wires used for the transmission of data between
boiler and chrono-thermostat.
CAR
V2
or chrono-thermostat On/Off electric
connection (Optional).
The operations described
below must be performed after having removed
the voltage from the appliance.
Any On/Off room
chrono-thermostat must be connected to clamps
40 and 41 eliminating jumper X40 (Fig. 3-2).
Make sure that the On/Off thermostat contact is
of the “clean” type, i.e. independent of the mains
supply, otherwise the P.C.B. would be damaged.
Any CAR
V2
must be connected to clamps 40 and
41 eliminating jumper X40 on the circuit board,
paying attention not to invert the polarity in the
connections (Fig. 3-2). 3-2). Connection with
the wrong polarity prevents functioning, but
without damaging the CAR
V2
The boiler can only
be connected to one remote control.
Important:
if the CAR
V2
remote control is used,
arrange two separate lines in compliance with
current regulations regarding electrical systems.
No boiler pipes must ever be used to earth
the electric system or telephone lines. Ensure
elimination of this risk before making the boiler
electrical connections.
Fig. 1-3
Fig. 1-4
POWER SUPPLY CABLE