3.4  CONVERTING THE BOILER TO 

OTHER TYPES OF GAS.

If the appliance needs to be converted to a 

different gas type to that specified on the data 

plate, request the relative conversion kit for quick 

and easy conversion.

Boiler conversion must be carried out by a 

qualified technician (e.g. After-Sales Technical 

Assistance Service).

To convert to another type of gas the following 

operations are required:

- disconnect the appliance;
-  replace the main burner injectors, making sure 

to insert the special seal rings supplied in the 

kit, between the gas manifold and the injectors;

- move jumper 16 (Fig. 3-3) to the correct 

position for the type of gas in use (Methane or 

L.P.G.);

-  to access adjustments on the circuit board, the 

cover must be removed from the dashboard by 

taking out the rear fixing screws;

- re-power the appliance;
- adjust the maximum heat power of the boiler;
- adjust the minimum heat power of the boiler;
- adjust (if necessary) the heating power;
- seal the gas flow rate regulation devices (if 

settings are modified);

- after completing the conversion, apply the 

sticker, contained in the conversion kit, near 

the data-plate. Using an indelible marker pen, 

cancel the data relative to the old type of gas.

These adjustments must be made based on 

the type of gas used, following the indications 

provided in the tables (Par. 3.16).

3.5  CHECKS FOLLOWING CONVERSION 

TO ANOTHER TYPE OF GAS.

After making sure that conversion was carried 

out with a nozzle of suitable diameter for the 

type of gas used and the settings are made at the 

correct pressure, check that:

- there is no flame in the combustion chamber;
-  the burner flame is not too high or low and that 

it is stable (does not detach from burner);

- the pressure testers used for calibration are 

perfectly closed and there are no leaks from 

the gas circuit.

N.B.: 

All boiler adjustment operations must be 

carried out by a qualified technician (e.g. After-

Sales Technical Assistance Service). 

Burner adjustment must be carried out using a 

"U" or digital pressure gauge connected to the 

gas valve outlet pressure point (Part. 4 Fig. 3-3), 

keeping to the pressure value provided in the 

tables (Par. 3.16) according to the type of gas for 

which the boiler is prepared.

3.6  POSSIBLE ADJUSTMENTS OF THE 

Fig. 3-3

P.C.B.

SIT 845 GAS Valve

  10  -  Phase fuse 3.15AF

  11  -  Neutral fuse 3.15AF

  12  -  Main switch

 13 -  Domestic hot water temperature trimmer

  14  -  RS232 computer interface

  15  -  Central heating temperature trimmer

  16  -  METHANE L.P.G. gas type selector

GAS VALVE.

•  Adjustment of boiler nominal heat output (see 

previous figure). 

- Turn the domestic hot water temperature 

selector (10 Fig. 2-1) to maximum;

- open the domestic hot water cock in order to 

prevent modulation from starting up;

-  adjust the nominal boiler power from the brass 

nut (3), keeping to the maximum pressure 

values provided in the tables (Par. 3.16) 

depending on the type of gas; 

- by turning it clockwise the heating potential 

increases and by turning it anti-clockwise the 

heating potential decreases.

• Adjustment of minimum boiler heat output 

(Fig. 3-3). 

N.B.:

 only proceed after having calibrated the 

nominal pressure.
Adjustment of the minimum thermal input is 

obtained by operating on the cross plastic screws 

(2) on the gas valve maintaining the brass nut 

blocked (3);

-  disconnect the power supply to the modulating 

coil (just disconnect a faston); by turning the 

screw in a clockwise direction, the pressure 

increases, and counter-clockwise it decreases. 

On completion of calibration, re-apply the 

power supply to the modulating coil. The 

minimum boiler power must not be adjusted 

to a pressure value below the levels stated in the 

tables (Par. 3.16) depending on the type of gas. 

N.B.:

 to adjust the gas valve, remove the plastic 

cap (6); after the adjustment, put the cap back on.

Key:

  1 -  Coil

  2  -  Minimum power adjustment screw

  3  -  Maximum power adjustment nut

  4  -  Gas valve outlet pressure point

  5  -  Gas valve inlet pressure point

  6  -  Protection hood

Содержание 3.018921

Страница 1: ...NIKE MINI 28 KW SPECIAL Instruction and warning booklet 1 040845ENG...

Страница 2: ...as boilers As for the other issues related to boiler installation e g safety in the work site environment protection injury prevention it is necessary to comply with the provisions specified in the re...

Страница 3: ...l heating system pressure 12 2 9 System draining 12 2 10 Anti freeze protection 12 2 11 Case cleaning 12 2 12 Decommissioning 12 3 Boiler start up initial check 13 3 1 Hydraulic diagram 13 3 2 Wiring...

Страница 4: ...ies personal responsibility and invalidates the warranty Installation regulations theseboilerscannotbeinstalledinbedrooms studio flats and bathrooms They also cannot be installed in rooms with wood or...

Страница 5: ...type used in the boiler which must comply with the regulations in force as insufficient levels can reduce generator output and cause malfunctions Ensure correct gas cock connection by following the m...

Страница 6: ...ergas chrono thermostats are connected with 2 wires only Carefully read the user and assembly instructions contained in the accessory kit On Offdigitalchrono thermostat Thechrono thermostat allows set...

Страница 7: ...dangerous situations for the user The flue ducts must be connected to the chimney or flue in the same room in which the appliance is installed or at most in the adjoining room and must comply with the...

Страница 8: ...intervenes in the eventofgassupplyfailureandchecktherelative intervention time check activation of the main switch located upstream of the boiler The boiler must not be started up even if only one of...

Страница 9: ...safety thermostat 6 Fumes hood 7 Delivery probe 8 Safety thermostat 9 System expansion vessel 10 Combustion chamber 11 Boiler circulator pump 12 3 bar safety valve 13 By pass 14 Three way valve motor...

Страница 10: ...onnected parts with easily flammable substances Never leave containers or flammable substances in the same environment as the appliance It is prohibited and dangerous to obstruct the air intake even p...

Страница 11: ...tacts resistance block LEDs 2 and 7 flash at the same time 04 Parasite flame block LEDs 1 and 7 flash at the same time 20 Loss of remote control communication LEDs 2 and 3 flash alternately 31 Insuffi...

Страница 12: ...ure via the valve located at the bottom of the boiler Fig 2 2 N B close the valve after the operation If pressure values reach around 3 bar the safety valve may be activated In this case contact a pro...

Страница 13: ...he exit of the appliance combustion products check that there is no backflow of combustion products into the room even during functioning of fans ensure activation of all adjustment devices seal the g...

Страница 14: ...ent interventions of the over heating safety thermostat It can depend on reduced water pressure in the boiler little circulation in the heating system the blocked pump or an anomaly of the boiler P C...

Страница 15: ...perations must be carried out by a qualified technician e g After Sales Technical Assistance Service Burner adjustment must be carried out using a U or digital pressure gauge connected to the gas valv...

Страница 16: ...tables Heating output The boiler is produced and calibrated in the central heating phase at nominal output Permanent reduction of the timer The boiler has an electronic timing device that prevents the...

Страница 17: ...with boiler in standby the function activates every 18 hours after the last boiler check power supply In case of functioning in domestic hot water mode the self check starts within 10 minutes after t...

Страница 18: ...anel 4 towards you taking care to remove the 2 fixing screws 5 3 16 HEAT OUTPUT N B gasflowratesrefertoheatingpowerbelowa temperature of 15 C and a pressure of 1013 mbar Burner pressure values refer t...

Страница 19: ...3994 Domestic hot water adjustable temperature C 38 77 Domestic hot water circuit flow limiter l min 11 Domestic circuit min pressure dynamic bar 0 3 Domestic hot water circuit max working pressure ba...

Страница 20: ...Model Cod Md Model code Sr N Serial Number CHK Check Cod PIN PIN code Type Type of installation ref CEN TR 1749 Qnw min Minimum DHW heat input Qn min CH minimum heat input Qnw max DHW maximum heat in...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...Europe S r o 059051 Poprad Matejovce SK Tel 421 524314311 Fax 421 524314316 IMMERGAS SPA ITALY CERTIFIED COMPANY UNI EN ISO 9001 2015 Design manufacture and post sale assistance of gas boilers gas wat...

Отзывы: