3.2  WIRING DIAGRAM.

Fig. 3-2

Key:

 

B1  -  Flow probe

 

B4  -  External probe (optional)

 CAR

V2

  -  Comando Amico Remoto remote 

control 

V2

 (optional)

 

E1  -  Ignition electrodes

 

E2  -  Detection electrode

 

E4  -  Safety thermostat

 

E6  -  Flue safety thermostat

 

F1  -  Neutral fuse

 

F2  -  Line fuse

  M1  -  Boiler circulator pump

  1 -  Primary

  2 -  Secondary

  3  -  Power supply 230Vac 50Hz

  4  -  Auxiliary outlet 230Vac 50Hz 

max. 2A

  5  -  Zones control unit (optional)

  6 -  Yellow/Green

  7 -  Blue

  8 -  Brown

  9 -  Red

 10 -  Black

 11 -  Grey

 12 -  White

  13  -  Central heating

  14  -  Domestic hot water

Remote Controls: the boiler is set-up for the 

application of the Comando Amico Remoto 

remote control 

V2

 (CAR

V2

) which must be 

connected to clamps 40 and 41 of the X9 

connector on the P.C.B. (respecting the polarity) 

and eliminating jumper X40.
Room thermostat: the boiler is designed for 

the application of the Room Thermostat (S20). 

Connect it to clamps 40 –41 eliminating jumper 

X40.
Connector X12 (RS 232) is used for automatic 

inspection for connection to the personal 

computer.

3.3 TROUBLESHOOTING.

N.B.: 

Maintenance must be carried out by a 

qualified technician (e.g. Technical After-Sales 

Assistance Service).
-  Smell of gas. Caused by leakage from gas circuit 

pipelines. Check sealing efficiency of gas intake 

circuit.

- Irregular combustion (red or yellow flame). 

Can be caused by: dirty burner, clogged 

lamellar pack, intake - exhaust terminal not 

installed properly. Clean the above components 

and ensure correct installation of the terminal.

- Frequent interventions of the over heating 

safety thermostat. It can depend on reduced 

water pressure in the boiler, little circulation 

in the heating system, the blocked pump or 

an anomaly of the boiler P.C.B. Check on the 

pressure gauge that the system pressure is 

within established limits. Check that radiator 

valves are not all closed.

- The boiler produces condensate. This can be 

caused by obstructions of the chimney or flues 

with height or section not proportioned to the 

boiler. It can also be determined by functioning 

at boiler temperatures that are excessively low. 

In this case, make the boiler run at higher 

temperatures.

- Frequent interventions of the flue safety 

thermostat. This can be caused by obstructions 

in the fumes circuit. Check the flue. The flue 

may be obstructed or by height or section 

not suitable for the boiler. Ventilation may be 

insufficient (see room ventilation point). In 

this case the boiler waits for 30 minutes, before 

trying to start up again. To exclude the meter, 

cut the voltage off by temporarily disconnecting 

the electrical power supply plug.

-  Presence of air in the system. Check opening of 

the special air vent valve cap (Fig. 1-8). Make 

sure the system pressure and expansion vessel 

factory-set pressure values are within the set 

limits; the factory-set value for the expansion 

vessel must be 1.0 bar, and system pressure 

between 1 and 1.2 bar.

- Ignition block and Chimney block. (See par. 

2.6 and 1.3 (electric connection).

  M30  -  Three-way valve

 

R5  -  Domestic hot water temperature 

trimmer

 

R6  -  Central heating temperature trimmer

  R10  -  Main selector

 

S4  -  Domestic hot water flow switch

 

S8  -  Gas type selector

  S20  -  Room thermostat (optional)

 

T2  -  Ignition transformer

  X40  -  Room thermostat jumper

 

Y1  -  Gas valve

 

Y2  -  Gas valve modulator

Содержание 3.018921

Страница 1: ...NIKE MINI 28 KW SPECIAL Instruction and warning booklet 1 040845ENG...

Страница 2: ...as boilers As for the other issues related to boiler installation e g safety in the work site environment protection injury prevention it is necessary to comply with the provisions specified in the re...

Страница 3: ...l heating system pressure 12 2 9 System draining 12 2 10 Anti freeze protection 12 2 11 Case cleaning 12 2 12 Decommissioning 12 3 Boiler start up initial check 13 3 1 Hydraulic diagram 13 3 2 Wiring...

Страница 4: ...ies personal responsibility and invalidates the warranty Installation regulations theseboilerscannotbeinstalledinbedrooms studio flats and bathrooms They also cannot be installed in rooms with wood or...

Страница 5: ...type used in the boiler which must comply with the regulations in force as insufficient levels can reduce generator output and cause malfunctions Ensure correct gas cock connection by following the m...

Страница 6: ...ergas chrono thermostats are connected with 2 wires only Carefully read the user and assembly instructions contained in the accessory kit On Offdigitalchrono thermostat Thechrono thermostat allows set...

Страница 7: ...dangerous situations for the user The flue ducts must be connected to the chimney or flue in the same room in which the appliance is installed or at most in the adjoining room and must comply with the...

Страница 8: ...intervenes in the eventofgassupplyfailureandchecktherelative intervention time check activation of the main switch located upstream of the boiler The boiler must not be started up even if only one of...

Страница 9: ...safety thermostat 6 Fumes hood 7 Delivery probe 8 Safety thermostat 9 System expansion vessel 10 Combustion chamber 11 Boiler circulator pump 12 3 bar safety valve 13 By pass 14 Three way valve motor...

Страница 10: ...onnected parts with easily flammable substances Never leave containers or flammable substances in the same environment as the appliance It is prohibited and dangerous to obstruct the air intake even p...

Страница 11: ...tacts resistance block LEDs 2 and 7 flash at the same time 04 Parasite flame block LEDs 1 and 7 flash at the same time 20 Loss of remote control communication LEDs 2 and 3 flash alternately 31 Insuffi...

Страница 12: ...ure via the valve located at the bottom of the boiler Fig 2 2 N B close the valve after the operation If pressure values reach around 3 bar the safety valve may be activated In this case contact a pro...

Страница 13: ...he exit of the appliance combustion products check that there is no backflow of combustion products into the room even during functioning of fans ensure activation of all adjustment devices seal the g...

Страница 14: ...ent interventions of the over heating safety thermostat It can depend on reduced water pressure in the boiler little circulation in the heating system the blocked pump or an anomaly of the boiler P C...

Страница 15: ...perations must be carried out by a qualified technician e g After Sales Technical Assistance Service Burner adjustment must be carried out using a U or digital pressure gauge connected to the gas valv...

Страница 16: ...tables Heating output The boiler is produced and calibrated in the central heating phase at nominal output Permanent reduction of the timer The boiler has an electronic timing device that prevents the...

Страница 17: ...with boiler in standby the function activates every 18 hours after the last boiler check power supply In case of functioning in domestic hot water mode the self check starts within 10 minutes after t...

Страница 18: ...anel 4 towards you taking care to remove the 2 fixing screws 5 3 16 HEAT OUTPUT N B gasflowratesrefertoheatingpowerbelowa temperature of 15 C and a pressure of 1013 mbar Burner pressure values refer t...

Страница 19: ...3994 Domestic hot water adjustable temperature C 38 77 Domestic hot water circuit flow limiter l min 11 Domestic circuit min pressure dynamic bar 0 3 Domestic hot water circuit max working pressure ba...

Страница 20: ...Model Cod Md Model code Sr N Serial Number CHK Check Cod PIN PIN code Type Type of installation ref CEN TR 1749 Qnw min Minimum DHW heat input Qn min CH minimum heat input Qnw max DHW maximum heat in...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...Europe S r o 059051 Poprad Matejovce SK Tel 421 524314311 Fax 421 524314316 IMMERGAS SPA ITALY CERTIFIED COMPANY UNI EN ISO 9001 2015 Design manufacture and post sale assistance of gas boilers gas wat...

Отзывы: