4 Setting the Light Effect Unit
into Operation
4.1 Installation
G
Always position the unit in such a way that a suf-
ficient air circulation is ensured during operation.
G
Always ensure a minimum distance of 50 cm to
the illuminated object.
Tightly screw the light effect unit via its mounting
bracket (1) to a suitable place, e. g. with a stable
mounting screw or a support for lighting units
(C hook) to a crossbar. To align the unit, release the
two locking screws (2) at the bracket, adjust the
desired inclination and retighten the screws.
4.2 Power supply
1) To
switch on
the unit, connect the mains cable
provided to a mains jack (16), then connect the
plug to a socket (230 V~ / 50 Hz). The display (5)
shortly shows
. Then the unit is ready for
operation and can be operated via a DMX light
controller (
chapter 6) or it runs automatically
through the control program adjusted (
chap-
ter 5).
2) To
switch off
, disconnect the mains plug from
the socket.
For a more convenient operation, it is recom-
mended to connect the unit to a mains socket
which is switched on and off via a light switch.
Caution:
The unit must
not
be connected to the
mains voltage via a dimmer!
For power supply of another light effect unit the
mains output jack (15) can be used if the total cur-
rent consumption does not exceed the rated cur-
rent of the fuse in the fuse support (17) [
type
plate and imprint on the unit]. The connection can
e. g. be made via the mains extension cable
AAC-170
/
SW from MONACOR. Thus, several
LED-640RGBW can be interconnected.
4.3 Basic settings
The following basic settings can be made via a
menu (
chapter 9.1) with the buttons MENU,
,
and ENTER (8). Press the button MENU repeat-
edly until the display (5) shows the desired func-
tion. Then press the button ENTER:
Note:
If you do not press any button for one minute, the
unit will stop the setting procedure and return to the normal
operating mode.
Blackout Mode on or off
Press the button
or
to select:
The light is also switched on without DMX
control signal. This adjustment must be
selected when operating the unit without
DMX controller.
The light beam is only switched on when a
DMX control signal is present at the jack
DMX INPUT (12). As soon as the DMX
controller is switched off, the light is
switched off as well.
To memorize, press the button ENTER.
Display on or off
Press the button
or
to select:
The display is always on.
The display is switched off approximately
60 seconds after you press the last button.
It is switched on again when you press the
next button.
To memorize, press the button ENTER.
Display mode
Press the button ENTER to select and to memorize
at the same time:
normal display
display turned by 180° for mounting upside
down
To exit the setting mode, keep the button MENU
pressed until the unit starts the operating mode
adjusted or wait for one minute.
WARNING
To prevent damage to your eyes,
never look directly into the light
source for a long time.
Please note that fast changes in light-
ing, e. g. flashing light, may trigger
epileptic seizures with photosensitive
persons or persons with epilepsy!
WARNING
Install the unit safely and expertly. If
it is installed at a place where people
may walk or sit under it, additionally
secure it [e. g. by a safety rope; lead
the safety rope through the ring
screw (14) and fix it in such a way
that the maximum falling distance of
the unit will not exceed 20 cm.]
14
GB