23
Replacing a Fuse
Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the
fuse burns out, the product will not function whatsoever. If this happens,
follow the directions below to do
so.
1.
Unplug the unit from electric power source.
2.
Insert a screwdriver into the slot in the fuse cover. Gently pry up the fuse cover. The fuse will come out.
3.
Remove the used fuse. If brown or unclear, it is burned out.
4.
Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to
use a fuse of the same type and specification. See the product specification label for details.
Rotating Gobo-wheel
Colorwheel
9 1
8 2
7
3
6 4
5
Fig. 7
Fig. 8
Troubleshooting
No Light, No Movement - All Products
This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps
below in sequence until a solution is found. Once the unit operates properly, do not carry out following
steps.
If the light effect does not operate properly, refer servicing to a technician.
Response: Suspect three potential problem areas: the power supply, the lamp, the fuse.
1.
Power supply. Check that the unit is plugged into an appropriate power supply.
2.
The LEDs. Return the
BEAM-
20LED Beam to your
IMG Stage Line
dealer.
3.
The fuse. Replace the fuse. See page 23 for replacing the fuse.
No Response to DMX
Response: Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card
malfunction.
1.
Check the DMX setting. Make sure that DMX addresses are correct.
2.
Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power.
Try your DMX control again.
3.
Determine whether the controller or light effect is at fault. Does the controller operate properly with
other DMX products ? If not, take the controller in for repair. If so, take the DMX cable and the light
effect to a qualified technician.