![Imesa D2W18 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/imesa/d2w18/d2w18_instructions-for-installation-use-and-maintenance-manual_2046343007.webp)
E190601X rev.6_ENG
May 30, 2022
7
out only by qualified and competent personnel.
The super centrifugation machines during transport are locked inside them (the cradle at the base) with stops,
to avoid the stress of the shock absorbers.
ATTENTION!
The latches must be removed, after the machine has been placed at and before it is fed.
To disassemble the latches, perform the procedure described below, referring to the figure. The figures are
indicative of the type of stops and not of the machine.
-
remove the back and front rings
-
unscrew the bolts that block the transport stops
-
dismantle transport stops
-
reassemble the panels in the original position
For "tilting" machines operate as described below:
Remove the back panel and the lower backrest, proceed to the removal of the transport stops.