4
Installation Instructions
Make sure that
Imenco’s Terms & Conditions
are followed when using this product.
4.1
Unpacking and testing
When having received the camera do a visual inspection for
damage of the packet or any of the parts.
The packet should include:
•
Orca II camera
•
User manual
•
Memory stick with SmartView
•
SmartView user manual
•
Pressure test certificate
•
Quality control certificate
•
Optional test Cable
4.2
Function test
A preliminary function test should be performed prior to full scale installation. This is to familiarize
the user with the control functions and to verify that the system is fully operational after shipment.
Follow these steps to power up and check the proper functioning of the camera:
1)
Acquire a cable that is terminated in one end with a connector compatible with the Orca II
camera connector as specified in
4.4.2
S
UBSEA CONNECTOR TYPE AND PIN
-
OUT
and the other end is
split into a Cat5e network cable with RJ45 termination for the computer as well as a DC-power
cable. Example of such cable is shown in
F
IGURE
9,
M
INIMAL TEST CABLE
2)
Clear necessary space on your working desk and gather the
a.
Orca II camera
b.
Power supply providing DC anywhere between 24V and 48V and minimum 20W
c.
Computer with SmartView installed
d.
The test cable mentioned above
3)
Do not power up the camera yet.
Lubricate the subsea connector as specified in section
4)
Connect the network cable and start the computer.
5)
Now turn on the DC power to the Orca II.
Indications that the Orca II has been properly powered up are: