SubVIS Orca II - User Manual
IMENCO AS
Visiting Address:
Kophaug 3, 5570 Aksdal, Norway
Office: +47 52 86 41 00
Org No: 923 005 749 MVA
Mail Address:
PO. Box 2143, 5504 Haugesund, Norway
Fax:
+47 52 86 41 01
www.imenco.com
10
3.1.1
Format of HTTP-API
Each HTTP API defines a specific
query
part of the URL to the Orca II camera HTTP server.
The Client must send a HTTP GET request to the camera in this general format:
http://
<IP address>
/hsc?
<query>
This could be entered in the address field of a Web browser and the Orca II camera would respond
with a message that would show up in the Browser window.
Here is an example of reading out an internal temperature from the camera
(assumed at address 192.168.1.2):
http://192.168.1.2/hsc?get_temperature=1
The HTTP GET Response would be a text string including the actual temperature in °C:
$31^
Some useful HTTP APIs are listed in
3.1.2
Video streaming
Streaming video can be received with a third party streaming media player such as VLC media player:
“rtsp://<Orca II IP address>:<port>/<name of video stream>
Note that such players may not be optimized for low latency.
Imenco’s SmartView is developed with lowest possible latency as a design requirement.
3.2
Minimum Working Distance and Zoom
Figure 4, Minimum Working Distances
1x
2x
3x