Chapter 2
Installation and Operation
14
Upgrading Module Firmware
This module’s firmware can be updated using the Magellan CCS Navigator HTTP
software upgrade tool. In order to perform these upgrades, your frame must be equipped
with a 6800
+
ETH module. See your frame manual for more information.
Changing Parameter Settings
You can change parameter settings for this product at the card-edge, or you can use CCS
software and hardware controls.
Card-Edge Controls
1
Rotate the hex switch (mode select rotary switch) to
0
.
2
Once the hex switch is set to
0
, toggle the navigation switch up or down to select a bank.
View the four control LEDs next to the navigation toggle switch to see which bank is
currently selected. (See
Table 2-4
.)
See
Table 2-5
on page 18 to view the various banks, hex switch positions, and
corresponding parameter options and values.
3
Rotate the hex switch to the parameter number (1 to 9) or letter (A to F) of the option you
want to set.
4
Toggle the navigation switch to select and set the value of the chosen parameter.
Table 2-4
Selected Bank as Indicated by Control LEDs
Bank
Select 2
Bank
Select1
Bank
Select 0
Bank
Number
Off
Off
Off
0
Off
Off
On
1
Off
On
Off
2
Off
On
On
3
On
Off
Off
4
On
Off
On
5
On
On
Off
6
On
On
On
7
Off
Off
Off
8
Off
Off
On
9
Off
On
Off
A (10)
Off
On
On
B (11)
On
Off
Off
C (12)
On
Off
On
D (13)
On
On
Off
E (14)
On
On
On
F (15)