![Imagine Selenio6800+ OP+VTX Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/imagine/selenio6800-op-vtx/selenio6800-op-vtx_installation-and-operation-manual_2045418014.webp)
Chapter 2
Installation and Operation
4
Maximum Frame Power Ratings
OP
+
VTX modules operate only in fan-cooled frames, subject to the limitations shown in
Table 2-2
. These modules cannot be installed in FR6802
+
DM or 6800/7000 series frames.
NOTE: To maintain proper temperatures, ensure the front panel is closed at all times, and
the fan module is fully operational.
Table 2-2
Frame Power Ratings
Frame Type
Power
Supply
Max. Frame
Power
Dissipation
Number
of Usable
Slots
*
Max. Power
Dissipation
Per Slot
OP
+
VTX Power
Requirements
FR6802
+
XF
AC
120 W
20
6 W
12 W per module
FR6802
+
XF48
DC
105 W
20
5.25 W
FR6802
+
QXF
AC or DC
120 W
20
6 W
FR6822
+
and
FR6822
+
QXFE
AC or DC
120 W
20
6 W
* Each front module requires two of these slots. Therefore, to calculate the maximum power dissipation available per module,
triple the rating shown in the Max. Power Dissipation Per Slot column.