Chapter 2
Installation
22
Configuring Third-Party SNMP Software Control
SNMP is an industry-standard protocol that allows other manufacturers’ control software to
remotely monitor and control the X50.
Harris provides MIB files that can be downloaded from the website. Two general MIB files
(
leitch.mib
and
ccsAlarm.mib
) set up the structure to define parameters and alarms. Once
these two MIBs are installed, you will want to install a MIB for each distinct module for
which you wish to set up third-party software control.
You can use any standard MIB browsing software with your X50.
1
Make the required network connections between the X50 unit(s) and your PC with installed
SNMP browser/control software.
The SNMP configuration process for the X50 directs the SNMP agent where to send alarms
(SNMP traps). This file must be modified before it is loaded back to the X50. For information
on configuring SNMP, see page 19.
2
Load the leitch.mib file into your SNMP browser/control software.
This MIB sets up the basic structure for product specific Harris MIBs. It can be found under
the
Private
>
Enterprise
branch, and sets up the leitchProducts and leitchCommon
sub-branches.
The
leitchCommon
branch is initially empty. The
leitchProducts
branch contains folders
for different families of Harris devices—for example,
LeitchX75
,
NEO
and
X50.
3
Load
ccsAlarm.mib
into your SNMP browser/control software.
This MIB adds a
ccsAlarms
sub-branch to the
leitchCommon
folder. When it is installed,
you will be able to receive traps with proper information as to where the alarms are
triggered from.
4
Load product-specific X50 MIB files into your SNMP browser/control software.
A product-specific MIB provides a clear path to the parameters and alarms on the device.
Harris MIBs can be downloaded from our website.
X50 MIBs will appear in the X50 folder under the
leitchProducts
5
Configure your MIB browser to connect to the unit by entering the
IP address
,
Port
(if you
have changed the Port from its default in the configuration), and other standard
configuration settings.
Your browser should now be able to connect to the SNMP agent running on the X50 unit. If
you wish to receive traps, start up the trap receiver in your MIB browser software.
Note:
To verify that your configurations are correct, you can walk MIB2.
Содержание Selenio X50
Страница 1: ...Installation and Operation Manual Selenio X50TM Broadcast Quality Up Cross Downconverter Version 4 0...
Страница 7: ...Version 4 0 August 2015 X50 Broadcast Quality Up Cross Downconverter Installation and Operation Manual...
Страница 8: ......
Страница 14: ...Preface Safety xiv...
Страница 18: ...Chapter 1 Introduction 4 Front and Back Views Figure 1 1 Front and Back Views...
Страница 112: ...Chapter 5 Specifications 98...
Страница 136: ...122...