Change the IP address by following these steps:
a
Press
Enter
to navigate to one of the four number sets in the octet.
b
Modify the address value by using the scroll knob to set a new number.
c
Press
Enter
to move to the next item in the octet, and then repeat step (b) above.
d
Press
Exit
when you are finished configuring the address.
4
Scroll to the
Subnet Mask
parameter, and then press
Enter.
If this is a new unit being configured, the default subnet mask displays. Otherwise, the
current subnet displays.
5
Repeat the procedure described in step 4, this time for the subnet mask.
6
Scroll to the
Gateway
parameter, and then press
Enter
.
If this is a new unit being configured, the default gateway displays. Otherwise, the current
gateway address displays.
7
Repeat the procedure described in step 3, this time for the gateway parameter.
8
Select
Save IP
, and then press
Enter
.
9
Select
Yes
option and then press
Enter
.
10
Press
Exit
to return to the
Setup
menu.
Rebooting the X50 is not required.
Setting the IP Addresses of Multiple Units
If you have multiple X50 systems that require network configuration, you will need to set
unique IP addresses and assign a subnet mask and gateway address for each of them one at
a time. The following procedure summarizes the required steps:
1
Apply power to the first X50 unit with a frame-mounted local control panel.
When ready for configuration, the main X50 menu shows on the display screen.
2
Configure the network settings for the first X50, as described in the procedure on page 11.
3
Restart the X50 unit.
4
Plug in the next X50 system, configure its network information, and then restart the unit.
Follow this procedure for all remaining X50 units that require configuration.
5
Connect all X50 systems and remote panels to a network hub or switch using a 10/
100Base-T Ethernet cable.
6
Ensure that all configured X50 units are detected on the network.
To do this, press
Remote
on the front panel. All X50 units configured with the same subnet
mask address will display (you will see a list of all detected IP addresses).
If a unit or RCP is not detected, ensure that the subnet mask address is accurate.
Alternatively, confirm that all units were restarted after configuring any network settings.
Содержание Selenio X50
Страница 1: ...Installation and Operation Manual Selenio X50TM Broadcast Quality Up Cross Downconverter Version 4 0...
Страница 7: ...Version 4 0 August 2015 X50 Broadcast Quality Up Cross Downconverter Installation and Operation Manual...
Страница 8: ......
Страница 14: ...Preface Safety xiv...
Страница 18: ...Chapter 1 Introduction 4 Front and Back Views Figure 1 1 Front and Back Views...
Страница 112: ...Chapter 5 Specifications 98...
Страница 136: ...122...