X50
Installation and Operation Manual
117
9
Gently press the circuit board back into place, taking care not to bend the pins on the left
side.
10
Install the six mounting screws supplied, and then re-attach the fan electrical connectors.
11
Replace the cover as described earlier, and then re-attach the two power cords.
Preventing a Broken Shaft Encoder
Version 2 units contain a nylon shoulder washer that effectively reduces the chance of
physical damage to the shaft encoder. Version 1 units can be retrofitted, using part number
142-100017Q00. To install this washer on a Version 1 X50 unit, follow these steps:
1
Remove the knob from its shaft by pulling it straight out.
2
Slide the shoulder washer over the shaft encoder as shown.
You may need to rotate the washer as you insert it into the hole.
Figure C-19.
Installation of Shoulder Washer
3
Replace the knob.
Slide washer
into hole