Chapter 3: Operation
Cross-Functional Parameter Changes
In some situations, when certain parameters are changed, other changes
are forced in associated parameters.
Table 3-1
and
Table 3-2
describe
those changes in the HOMS
+
OP
+
and OHDS
+
OP
+
, respectively. The
value of
x
in
Table 3-1
and
Table 3-2
is 1, 2, 3, 4, 5, 6, 7, or 8.
Table 3-1.
HOMS
+
OP
+
(L4/U4/L8/U8) Cross-Functional Parameter Changes
Parameter
Option
Affected Parameter Forced Setting
Ch-x Reclock
Mode
Auto
Rate x Fb
Status feedback from reclocker
Ch-x
ASI Mode
Enable
• 143
• 177
• 270
• 360
• 540
• HD
Rate x Fb
143, 177, 270, 360, 540, HD,
respectively
Ch-
x
ASI Mode
Disable
Ch-x Laser Enable Enable
Ch-x Laser Status
(Read from hardware)
Disable
Ch-x Laser Status
Disable
Table 3-2.
OHDS
+
OP
+
(L4/U4/L8/U8) Cross-Functional Parameter Changes
Parameter
Option
Affected Parameter Forced Setting
Ch-x Reclock
Mode
Auto
Rate x Fb
Status feedback from reclocker
Ch-x
ASI Mode
Enable
• 143
• 177
• 270
• 360
• 540
• HD
Rate x Fb
143, 177, 270, 360, 540, HD
respectively
Ch-x
ASI Mode
Disable