HOMS
+
OP
+
and OHDS
+
OP
+
Installation and Operation Manual
17
Chapter 2: Installation
3. Gently remove the outer and inner protective caps from the laser
connections. (see
Figure 2-1 on page 14
).
CAUTION
Microscopic dust or other contaminants can seriously impair or
disable a fiber optic network. Observe strict cleaning procedures.
Do not touch the end of the fiber.
4. Follow the fiber cleaning instructions that begin on
page 19
.
5. Ensure that your front module matches with a corresponding back
module of the same name.
6. With the locking latch in the up position, slide the module into the
guides on the frame floor.
7. When the module edge is flush with the guide, close the extractor
handle, and then slide the locking latch into the down position.
The module is properly seated when its edge is flush with the guide
edge and the extractor handle closes.
8. Close the front panel to ensure proper frame ventilation.
To prevent overheating, keep the front panel closed and all back
module plate slots covered during operation.