background image

 

 

 

 

ADC-A12C31 Operator’s Handbook Rev. A   

 

 

P. 8 

 

 

 

Introduction 

The ADC-A12C31 is a precision analog clock containing a stepper motor drive and advanced 
microprocessor controlled electronics. 
 

IRIG-B 

Defined by the Range Commanders Council, U.S. Army White Sands Missile Range. IRIG (Inter-range 
Instrumentation Group) is used by military, government, power industry and many other commercial 
and industrial applications. The ADC-A12C31 decodes IRIG-B in both a 1 kHz modulated (IRIG-B1) and 
un-modulated/pulse width coded/DC level shifted (IRIG-B0) format. All formats of IRIG-B time code 
decoded by the ADC-A12C31 use the time of year information BCD (Binary Coded Decimal). All 
formats of IRIG-B time code decoded by the ADC-A12C31 also use the extended year/date and time 
zone information in the control functions as defined by the IEEE 1344 specification. SBS (Straight 
Binary Seconds) information is not decoded. Manchester format/encoding is not supported. 
 
The ADC-A12C31 can be configured for world-wide time zone offset and automatic DST 
(Daylight Saving Time) adjustment and allows for reliable, accurate and maintenance free 
operation. Use of the automatic DST feature requires that the clock be enabled to accept the 
time code date encoding, using the USB port and ADC-Set (Clock Time Code Display) USB 
Configuration Utility (i.e. Windows software application). The time code reference must 
provide date encoding in the control bits/fields to date encoding standard for SMPTE or the 
IEEE-1344 year encoding for IRIG-B. 

 
SMPTE 

Society of Motion Picture and Television Engineers format is available in frame rates of 24, 25, and 
30 frames second. The ADC-A12C31 time code clock supports all three formats.

 

All formats of 

SMPTE time code decoded by the ADC-A12C31 use the full date information in the user bits as 
defined by the standard. 
 

 

The ADC-A12C31 does not support decoding of SMPTE drop-frame, reverse running, VITC, 
NTSC, color frame, blackburst or other video time code formats and synchronization options. 

 

Please refer to the “Specifications” section of this document for additional details. 

 

 

Features 

 

RTC (Real Time Clock) backup retains time during loss of power or reference. 

 

Self-correcting hands once power and/or Time Code reference is established. 

 

Time zone offsets 

 

DST configuration. 

 

TCXO (Temperature Compensated Crystal Oscillator) for +/- 1 min per year accuracy when 
no reference available (freewheeling). 

 

All configuration settings retained in non-volatile flash memory. 

 

Second Hand with sweep or step option. 

 

Self-correcting hands after loss of power and/or time code reference and DST changes. 

 

Loss of LTC status LED on clock face, located at the 6 o’clock position.

 

Содержание ADC-A12C31

Страница 1: ...Delivering the Moment ADC A12C31 Master Clock Revision A P061 0024 Installation and Operation Manual...

Страница 2: ...time or an unknown time in the future This publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers Imagine Communications reserves the righ...

Страница 3: ...Environment 14 Status LED 14 Correction Behavior 14 Hand Position 15 Time Zone Offsets 15 Daylight Saving Time 15 Pre 2007 Standard U S A and Canada 16 Post 2006 Standard U S A and Canada 16 EU Standa...

Страница 4: ...tery Circuit 33 Maintenance Free Rechargeable Battery 33 Operating Storage Temperature Humidity 33 Size and Weight 33 Troubleshooting 34 The time is incorrect 34 Not displaying the correct local time...

Страница 5: ...ADC A12C31 Operator s Handbook Rev A P 4 This page intentionally left blank...

Страница 6: ...1 U S A All rights reserved This publication supersedes all previous releases No part of this documentation may be reproduced in any form or by any means or used to make any derivative work without pe...

Страница 7: ...00 3 2 2000 Harmonic Current Emission EN61000 3 3 1995 A1 2001 Voltage Fluctuations Flicker Low voltage directive 2006 95 EC Tested and Conforms to the following Safety standards EN60950 1 2001 Safety...

Страница 8: ...r the WEEE directive except that Category 8 Medical Devices and Category 9 Monitoring and Control Instruments which are under WEEE are excluded from the RoHS directive The time display product ADC A12...

Страница 9: ...oding using the USB port and ADC Set Clock Time Code Display USB Configuration Utility i e Windows software application The time code reference must provide date encoding in the control bits fields to...

Страница 10: ...mmunications Corporation warranty may be void as a result of the failure to respect the precautions stated above Only qualified persons are authorized to carry out maintenance on this device Read this...

Страница 11: ...poses Refer to your sales order for actual items shipped ADC A12C31 analog clock Mounting bracket with retaining screw CD ROM ADC Set USB Configuration Utility and Operator s Handbook Power cord ADC A...

Страница 12: ...Operator s Handbook Rev A P 11 Connect the 50 ohm RG59 coaxial cable not supplied to the BNC connector located on the back panel Insert the AC power cord into the IEC power connector located on the b...

Страница 13: ...clock Do not route power or signal cables between the case and the wall along the exterior of the wall which may pinch the power or signal cable and create a hazardous condition A mounting bracket is...

Страница 14: ...ADC A12C31 Operator s Handbook Rev A P 13 This page intentionally left blank...

Страница 15: ...Status LED The red LED on the ADC A12C31 clock face located at the 6 00 indicates LED STATE STATUS INDICATION Off The clock acquired valid time code and has synchronized its internal RTC to the time...

Страница 16: ...the configuration mode to the use of the DIP switches the unit must be reset to factory default As shown on page 22 Time Zone Offsets All time code analog clocks maintain time as UTC A time zone offse...

Страница 17: ...ay of October Please carefully consult the section entitled Device Settings for details on setting daylight time To ensure proper hands free year around operation DST adjustments must be configured us...

Страница 18: ...ADC A12C31 Operator s Handbook Rev A P 17 This page intentionally left blank...

Страница 19: ...itch software configuration offset options set to off in order to display UTC time This is the factory default configuration is defined as SETTING CONFIGURATION SELECTION Disabled Time Zone Offset Dis...

Страница 20: ...offset OFF OFF ON OFF 5 hour offset ON OFF ON OFF 6 hour offset OFF ON ON OFF 7 hour offset ON ON ON OFF 8 hour offset OFF OFF OFF ON 9 hour offset ON OFF OFF ON 10 hour offset OFF ON OFF ON 11 hour o...

Страница 21: ...8 DST adjustment disabled OFF OFF default US Canada DST enabled ON OFF US standard through Fall 2006 US DST enabled OFF ON new US standard Spring 2007 EU DST enabled ON ON European Union The incoming...

Страница 22: ...OFF 70 OFF ON 100 ON ON S2 5 This switch is currently undefined and reserved for future use Function S2 5 Reserved OFF default Reserved ON S2 6 Set the second hand motion mode Function S2 6 Sweep cont...

Страница 23: ...hen doing comparisons To adjust the hands 1 Select Set using switch S2 8 ON 2 Select either the 12 00 00 OFF or 6 00 00 ON position using switch S2 7 3 Depress and release either button B1 or B2 to mo...

Страница 24: ...switches in the off position This default configuration results in the time displayed as Time Zone Offset Daylight Saving Time Time Code Date Encoding None Disabled Disabled Reset Factory Default Con...

Страница 25: ...ed with the time code clock Installation To install the software program on your server workstation PC complete the following steps 1 Insert the CD Time Code Product that shipped with your clock 2 Run...

Страница 26: ...e a USB cable not supplied and connect to the PC The Windows Plug and Play manager will detect a new USB device and request device drivers If Windows is unable to install the USB device drivers the sy...

Страница 27: ...his display update is not precise but is meant to give you a view of the clock display time for basic troubleshooting and maintenance purposes Also included is a Time Code Status which displays the ty...

Страница 28: ...e and click OK to close the window Changes are applied when you click OK Daylight Saving Time Configure and or enable the daylight saving function by clicking the Daylight Saving Time button North Ame...

Страница 29: ...ic detection and gain control circuit for the incoming SMPTE 30 25 24 fps longitudinal linear time code or for IRIG B 0 pulse width modulated or IRIG B 1 amplitude modulated time code To support commo...

Страница 30: ...be set to the time of the PC or a manual time and date can be entered Practical use of this feature requires the clock to be removed from the time code reference When the clock has access to a valid t...

Страница 31: ...to set clock 3 Enter the correct hour minute and second currently displayed on the face of the clock If the second is not currently aligned on a second mark you can nudge the second hand forward incr...

Страница 32: ...ADC A12C31 Operator s Handbook Rev A P 31 This page intentionally left blank...

Страница 33: ...drop frame IRIG B 1 1kHz amplitude modulated 3 1 modulation ratio IRIG B 0 dc offset level shifted un modulated pulse width modulated TTL level Nominal Level 1 5 Vpp 0dB 600 Level Range 0 175 12 Vpp...

Страница 34: ...holdover without applied external power Clock hand alignment settings are maintained in non volatile flash and are not affected by either loss of power or internal battery voltage Operating Storage T...

Страница 35: ...es 5 The time code reference to the ADC A12C31 is not a recognized format Verify that your time code reference is providing one of the time code formats that the ADC A12C31 can decode Not displaying t...

Страница 36: ...The date shown in the status window of ADC Set configuration utility is always 01 01 2000 Possible reasons solutions 1 Your time code reference is not providing date year information The DST adjustmen...

Страница 37: ...If your clock has a stainless steel case a cleaner and polish designed for use on stainless steel is recommended Use a recommended product to maintain and protect the stainless steel finish while resi...

Страница 38: ...he lens Don t use abrasive or highly alkaline cleaners Don t use paper towels paper products rayon or polyester cloths to clean or dry the lens Don t scrape the lens with squeegees razor blades or oth...

Страница 39: ...tach a tag to the unit with the following information Your company name address and telephone number The name of the contact person at your company The RA number The unit serial number An explanation...

Отзывы: