ADC-A12C31 Operator’s Handbook Rev. A
P. 19
DIP switch bank 1 (S1) configures Time Zone Offset & Daylight Savings Time
S1.1, S1.2, S1.3, and S1.4
Time zone hour offset:
Hour offset
S1.1
S1.2
S1.3
S1.4
0 hour offset
OFF
OFF
OFF
OFF
(default)
1 hour offset
ON
OFF
OFF
OFF
2 hour offset
OFF
ON
OFF
OFF
3 hour offset
ON
ON
OFF
OFF
4 hour offset
OFF
OFF
ON
OFF
5 hour offset
ON
OFF
ON
OFF
6 hour offset
OFF
ON
ON
OFF
7 hour offset
ON
ON
ON
OFF
8 hour offset
OFF
OFF
OFF
ON
9 hour offset
ON
OFF
OFF
ON
10 hour offset
OFF
ON
OFF
ON
11 hour offset
ON
ON
OFF
ON
12 hour offset
OFF
OFF
ON
ON
S1.5
Additional ½ hour time offset (as set by switch positions 1-4).
Function
S1.6
No ½ hour offset
OFF
(default)
Enable ½ hour offset
ON
S1.6
Negative/Positive time zone offset (as set by switch positions 1-5).
Function
S1.5
Time offset is negative
OFF
(default)
Time offset is positive
ON