ADC-A12C31 Operator’s Handbook Rev. A
P. 21
DIP switch bank 2 (S2) configures how Time Code Control Bits/Fields are handled.
S2.1 and S2.2
Time code Control Bits or Control Fields
Hour offset
S2.1
S2.2
No additional encoding
OFF
OFF
(default)
IRIG 1344 & SMPTE
ON
OFF
Reserved for future use
OFF
ON
Reserved for future use
ON
ON
S2.3 and S2.4
Control the face plate illumination level
Illumination Level
(Brightness)
S2.3
S2.4
0%
OFF
OFF
(default)
35%
ON
OFF
70%
OFF
ON
100%
ON
ON
S2.5
This switch is currently undefined and reserved for future use.
Function
S2.5
Reserved
OFF
(default)
Reserved
ON
S2.6
Set the second hand motion mode
Function
S2.6
Sweep (continuous)
OFF
(default)
Step (pulse)
ON
S2.7
Calibrate hands to position. Used in conjunction with S2.8 “ON” to set the clock hands
Function
S2.7
Set to 12:00:00
OFF
(default)
Set to 6:00:00
ON
S2.8
Used in conjunction with S2.7 to set the clock hands
Function
S2.7
Run
OFF
(default)
Set
ON
The ADC-A12C31 will accept switch changes dynamically. It is not necessary to restart or
cycle the power of the ADC-A12C31 for the device to accept the new settings.
Содержание ADC-A12C31
Страница 1: ...Delivering the Moment ADC A12C31 Master Clock Revision A P061 0024 Installation and Operation Manual...
Страница 5: ...ADC A12C31 Operator s Handbook Rev A P 4 This page intentionally left blank...
Страница 14: ...ADC A12C31 Operator s Handbook Rev A P 13 This page intentionally left blank...
Страница 18: ...ADC A12C31 Operator s Handbook Rev A P 17 This page intentionally left blank...
Страница 32: ...ADC A12C31 Operator s Handbook Rev A P 31 This page intentionally left blank...