Chapter 1
Installation
10
Adequate airflow
— The NEXIO frames require adequate airflow
around the chassis to provide sufficient cooling. All components draw
air in through the front and exhaust via the rear of the frame. The
surfaces must be clear of obstructions to provide proper air circulation
and cooling.
External device connections
— Video monitors and all connections
to external devices should be available and in working order.
Cable clearance
—
Provide at least 2 inches of clearance in the rear
of the rack for cabling.
Insure that the rack is anchored to the floor so that it cannot tip
over when the NX1010 is extended out of the rack.
Refer to the
NEXIO Safety and Compliance Information
booklet for
detailed safety and compliance information.