Manual
Page 89
Error codes, part 2
Error # Error message shown in
the display
Error message sent to
application
Problem description
11
Setting does not exist.
The settings does not exist.
12
Invalid user docsize.
The size of the user format is invalid.
14
Invalid resolution or color
mode.
Either the resolution or the color
mode is invalid.
20
E20 MOTOR 1 (O)
SCAN DRIVE
Motor 1 (Scan drive): End
switch permanently open.
The home position switch is
permanently open. The mechanics of
the corresponding motor could be
blocked or the switch/cable is
defective.
21
Error 21 Motor 1:
Transport locked
Motor 1 / PCI 1 (Box drive):
Transport locked
30
File format not supported.
The specified file format is not
supported or it is invalid in
combination with the color mode.
31
Preview not possible
The application specified an invalid
preview scale. Not all scale factors
are allowed with all image sizes.
32
Invalid color conversion
The application changed the color
depth between scanning and image
transfer and a conversion between
these modes is not possible.
Example: scan in binary, then
changed color mode to truecolor.
33
No image available
The application attempted to get an
image from the scanner and there
was no scan since the device was
turned on.
55
E55 WRONG S2N HW
CCD PORTS
Wrong S2N board detected
(not enough CCD ports)
The S2N board found is not the right
one for this device. Error can occur
after a repair/exchange. Exchange
with correct board.
56
Error 56: S2N Board: wrong
revision
Wrong S2N Board detected
(Revision not OK)
The S2N board found is not the right
one for this device. Error can occur
after a repair/exchange. Exchange
with correct board.