System Restore
36
System Restore to Factory Defaults
The recovery procedure is a simple process:
Step Action
1
Turn off the scanner either from the touchscreen, from the
Scan2Net application currently in use, or by pressing the POWER
button. If the device does not go into standby mode, press and hold
the POWER button for more than 5 seconds to hard-switch the
scanner into standby mode. If the device does not hard-switch into
stand-by mode, press the MAIN SWITCH to the "0" position to turn
off the scanner.
Make sure that the following process is not interrupted by a hard
shutdown or power failure.
If this process is interrupted, loss of the system restore point is
possible, so the SSD must be physically replaced.
The following process cannot be influenced by the user.
Step Action
2
Make sure the main power is on and the scanner is in standby
mode.
3
Press and hold the red RESET button on the back of the scanner
before turning it on! Turn on the scanner by pressing the POWER
button. Note: During the power-up process, the RESET button must
be pressed and held until it lights up continuously!
4
Restoration of the file system will begin immediately. This process
takes about 1 - 2 minutes. At the end of the recovery process, the
scanner will automatically reboot.