Installation site
19
Installation site
Environmental conditions
When operating the scanner, make sure that the room is well ventilated to
ensure the operating conditions.
The installation site must be chosen so that
•
the side distance between scanner and wall is at least 100 mm (4 inch),
•
the distance between the back of the scanner and the wall is at least 50
mm (2 inch),
•
the distance to a door or room entrance is at least one meter.
Place the scanner on a flat and solid base. The load bearing capacity of the
base must correspond to the device weight (max. 50 kg / 110 lbs.). The
dimensions of the base must match the floor space required by the
scanner.
After changing from a cold to a warm environment, allow at least one
hour for the scanner to adjust to the ambient temperature before
turning it on.
When the scanner changes from a cold to a warm environment,
condensation moisture may form inside the housing.