12
Adjusting the minimum gas
fl
ow
When installing the cooker you must check that the minimum gas
fl
ow of the burners on the hob is correctly
regulated.
If the type of gas is changed the minimum
fl
ow
must also be adjusted
. T
he regulating procedure is as
follows.
A)
Burners on the hob
1.
Light one burner at a time and turn the
fl
ame
up to maximum.
2.
Remove the knob of the corresponding gas tap and insert a screwdriver in the end part of the tap or in the
screw (
fi
g. 6, 7).
3.
Turn the tap to minimum position.
4.
Unscrew, turning to the left, to increase the
fl
ame, or
screw to the right to decrease it.
5.
Refer to the table below for adjustment settings
.
Fig. 6
Fig. 7
NOZZLE ADJUSTMENT TABLE
SR
R
Wok
Nominal Gas
Consumption MJ/h
6,80
12,00
16,00
NATURAL GAS
1,18
1,55
1,80
ULPG
0,69
0,90
1,08
NATURAL GAS
1/2
1/2
1-1/8
ULPG
Fully Closed
Fully Closed
Ø mm
by-pass screw adjustment*
ADJUSTMENTS
NATURAL GAS
ULPG
6,30
10,70
15,00
1/8
*
Bypass screw adjustment is specified as number of turns anticlockwise from fully closed position.