ELECTRICAL CONNECTION
The appliances are prepared for connection to the voltage indicated on the data plate.
Before connecting the appliance to the mains verify that:
- the electromagnetic switch’s characteristics or those of the socket can support the equipment’s
load: see data on the plate.
- the mains supply must be f tted with an effective earth.
The appliance is supplied with a 1.2 / 1.8 meter cable, according to the model, without plug; connection must
be made taking into consideration that the yellow green cable is the earth and must nev er be interrupted,
not even by the switch. The socket must be visible and accessible in order to disconnect the appliance easily.
For direct connection to the mains, it is necessary that:
- the safety valve and the domestic supply can support the appliances’ load (see rating plate)
- the supply system is equipped with an eff cient earth connection
- the switch or circuit breaker, with minimum 3 mm gap, is easily accessible once the appliance is installed
- means for disconnection must be incorporated in the f xed wiring in accordance with the wiring rules.
The yellow-green earth must never be interrupted not even by the switch. The
power cable must be placed in such a way to not come into contact with surfa-
ces 50°C hotter than the environment. In case it is necessary to substitute the
power cable contact the technical assistance service.