8
INSTALLATION
Positioning
Do not install in places with poor ventilation and
high temperatures, or locations in direct sunlight
or subject to weathering. Avoid proximity to heat
sources.
Warning! Make sure, once the installation is
complete, there are no obstacles to the door
opening.
Warning! Do not use extensions to the power
cable in order to avoid overheating problems.
Note: for the proper operation of the appliance an
air fl ue of at least 250 cm
2
is required (Fig. 5) on the
rear of the appliance.
Warning! Once the positioning is complete, se-
cure the appliance with suitable screws.
Fig. 5 - Size of the built-in niche
Ambient temperature and air exchange
Appliance performance is guaranteed up to an air temperature of 32°C provided that the air exchange is as
described in paragraph “Positioning”.
Final checks
Once the positioning and electrical connections are complete check the following:
• the electrical connection is correct;
• wait at least 4 hours before turning on the appliance to allow the thermodynamic circuit to stabilise.
Safety and control systems
The appliance is equipped with systems that ensure safety and allow control during operation:
• general protection fuse on the power cable to protect against short circuits and overloads;
• temperature cut-off on the compressor in the event of overload or operating anomalies;
• double temperature cut-off on the heating element;
• inner liner temperature probe, controlled by the power board.