Installation Manual Ilumen PID Box Mini v1.3 

 

 

11

 

T

ECHNICAL DATA

 

 

Technical data 

ILUMEN PID BOX MINI 

 

 

PV array / inverter input 

 

Input PV voltage range 

80 - 1000 V 

Output voltage to ground 

Up to 1250 V 

Maximum PV current 

20 A 

Maximum output current in operation 

5 mA 

 

 

GRID (AC) 

 

Nominal AC voltage 

100 to 240 V 

Nominal AC grid frequency 

47 to 63 Hz 

Power consumption in standby operation 

< 0.2 W 

Typical power consumption in operation 

8 W 

Maximum power consumption 

20 W  

 

 

General data 

 

Dimensions (W x D x H) 

263 x 140 x 72 mm 

Weight 

1.440 g 

Operating temperature range 

-25 to 60 °C (-13 to 140 °F) 

Environmental conditions 

IP44 - indoor use only (IP65 optional) 

PV connectors 

MC4 

 

 

Configuration 

 

One ILUMEN PID BOX MINI for 2 MPPT 

 

Maximum one MPPT per input (A/B) 

 

None of the connected solar module poles may 
become grounded

 

 

 

 

Communication 

 

Optional 

GPRS 

 

 

Various 

 

Warranty 

Up to 20 years 

Certificates 

www.ilumen.be 

Registration before use 

www.myilumen.be 

 

 

Содержание PID Box Mini

Страница 1: ...ILUMEN PID SOLUTION ILUMEN PID BOX MINI INSTALLATION MANUAL Ilumen PID Box Mini Version 1 3...

Страница 2: ...rostatic discharge 4 3 Scope of delivery 4 4 Product description 4 5 Mounting 4 5 1 Mounting location requirements 4 5 2 Mounting the Ilumen PID Box Mini 5 6 Electrical connections 5 6 1 Earth connect...

Страница 3: ...PID Box Mini ensure that the permitted operating range of each component is maintained at all times Before using the Ilumen PID Box Mini you have to obtain the appropriate approval from the manufactu...

Страница 4: ...nual 4 PRODUCT DESCRIPTION The Ilumen PID Box Mini is placed between the inverter and the solar array strings The power of the strings goes through the PID Box entering on one side and leaving on the...

Страница 5: ...ion is to have a single outlet with a single circuit breaker of 16A 6 1 EARTH CONNECTION To receive the best result the frames of the solar modules must be connected to the earth connector of the Ilum...

Страница 6: ...be terminated with a corresponding sealing plug Attention If you work with inverters with multiple MPPT s you cannot mix the PV arrays from multiple MPPT s Attention The maximum current that can pass...

Страница 7: ...e To start up the Ilumen PID Box Mini plug in the DC power supply into a standard EU outlet This outlet must be on at all times Next see if the LED light on the Ilumen PID Box Mini starts burning Afte...

Страница 8: ...to the frames of the PV modules and check the interconnections between the PV casings 4 Disconnect the PV array cables from the inverter 5 Connect the PV array cables to the Ilumen PID Box Mini inputs...

Страница 9: ...connectors going to the PV arrays and then disconnect the lines going to the inverter When all electrical connections are disconnected you can dismount the Ilumen PID Box Mini 10TROUBLESHOOTING 10 1...

Страница 10: ...n standby operation 0 2 W Typical power consumption in operation 8 W Maximum power consumption 20 W General data Dimensions W x D x H 263 x 140 x 72 mm Weight 1 440 g Operating temperature range 25 to...

Страница 11: ...Ilumen 11 Installation Manual Ilumen PID Box Mini v1 3 12CONTACT Ilumen bvba Ambachtsstraat 19 3980 Tessenderlo Belgium Tel 32 13 30 61 77 info ilumen be www ilumen be...

Отзывы: