background image

Ilumen 

 

9

 

Installation Manual Ilumen PID Box Mini v1.3 

 

 

9)

 

Turn the DC switch from the inverter back on followed by the AC side of the PV plant

 

9

 

D

ECOMMISSIONING THE 

I

LUMEN 

PID

 

S

OLUTION

 

Switch off the Ilumen PID Box Mini. Disconnect the Ilumen PID Box Mini from the AC grid. Wait 
for minimum 20 minutes. Make sure the AC cannot be plugged in again. Disconnect the DC 
switch from the inverter and wait until it is discharged. Disconnect all DC connectors going to 
the PV arrays and then disconnect the lines going to the inverter. When all electrical connections 
are disconnected you can dismount the Ilumen PID Box Mini. 

10

 

T

ROUBLESHOOTING

 

10.1

 

N

O GOOD 

PID

 REGENERATION

 

If the modules are not regenerating or not regenerating fast enough you should check following 
things: 

 

Control the grounding of the system. If necessary you should place additional 
interconnections. 

 

Is the Ilumen PID Box Mini properly connected to the grid? 

 

Is the DC power supply properly connected (is its indication light burning)? 

 

Let an expert check if the problem you’re having with the yield is caused by PID 

 

 

Содержание PID Box Mini

Страница 1: ...ILUMEN PID SOLUTION ILUMEN PID BOX MINI INSTALLATION MANUAL Ilumen PID Box Mini Version 1 3...

Страница 2: ...rostatic discharge 4 3 Scope of delivery 4 4 Product description 4 5 Mounting 4 5 1 Mounting location requirements 4 5 2 Mounting the Ilumen PID Box Mini 5 6 Electrical connections 5 6 1 Earth connect...

Страница 3: ...PID Box Mini ensure that the permitted operating range of each component is maintained at all times Before using the Ilumen PID Box Mini you have to obtain the appropriate approval from the manufactu...

Страница 4: ...nual 4 PRODUCT DESCRIPTION The Ilumen PID Box Mini is placed between the inverter and the solar array strings The power of the strings goes through the PID Box entering on one side and leaving on the...

Страница 5: ...ion is to have a single outlet with a single circuit breaker of 16A 6 1 EARTH CONNECTION To receive the best result the frames of the solar modules must be connected to the earth connector of the Ilum...

Страница 6: ...be terminated with a corresponding sealing plug Attention If you work with inverters with multiple MPPT s you cannot mix the PV arrays from multiple MPPT s Attention The maximum current that can pass...

Страница 7: ...e To start up the Ilumen PID Box Mini plug in the DC power supply into a standard EU outlet This outlet must be on at all times Next see if the LED light on the Ilumen PID Box Mini starts burning Afte...

Страница 8: ...to the frames of the PV modules and check the interconnections between the PV casings 4 Disconnect the PV array cables from the inverter 5 Connect the PV array cables to the Ilumen PID Box Mini inputs...

Страница 9: ...connectors going to the PV arrays and then disconnect the lines going to the inverter When all electrical connections are disconnected you can dismount the Ilumen PID Box Mini 10TROUBLESHOOTING 10 1...

Страница 10: ...n standby operation 0 2 W Typical power consumption in operation 8 W Maximum power consumption 20 W General data Dimensions W x D x H 263 x 140 x 72 mm Weight 1 440 g Operating temperature range 25 to...

Страница 11: ...Ilumen 11 Installation Manual Ilumen PID Box Mini v1 3 12CONTACT Ilumen bvba Ambachtsstraat 19 3980 Tessenderlo Belgium Tel 32 13 30 61 77 info ilumen be www ilumen be...

Отзывы: