iLOQ Oy • Oulu, Finland • www.iLOQ.com • iLOQ is registered trademark of iLOQ Oy •
©2018 iLOQ Oy. All Rights Reserved •
11. GENERAL NOTES
1. To meet the German VdS (VdS Schadenverhütung GmbH) requirements class CZ+ on
burglary threatened doors use D50S.XX0A.SD high security cylinder installed with a VdS
approved security lock furniture of class B or C. Such security lock furniture corresponds to
DIN 18 257 class ES 2 and ES 3.
2. To meet the Dutch SKG*** requirements use the D50S.XXXA.SD high security cylinder.
Consult iLOQ sales representative for correct configuration.
3. Before fitting the cylinder to a fire/smoke resisting door, the fire certification should be
examined to ensure conformity. Consult iLOQ sales representative for correct configuration.
4. The iLOQ cylinders are successfully tested according the EN 1634-1 (EUFI29-19003368) for
120 minutes in a hinged single leaf steel door.
5. In the case the panic mechanism of the panic mortise locks can be blocked or influenced in a
negative way by the cylinder cam, it is mandatory to install the panic cylinder (D50S.7xx).
The use of the other cylinder types (D5S.1xx/2xx/3xxx etc.) are only allowed if the lock do not
need a specific cam position resp. the cam could not block the panic functionality. Please
double-check the letter of conformity of the mortise lock manufacturers.
6. When used in combination with panic locks, it is essential to ensure after installation that all
parts of the lock are in an operational condition and that the panic function of the mortise lock
is guaranteed.
7. Care should be taken to ensure that any seals or weather-stripping fitted to the complete
door assembly, does not inhibit the correct operations of the cylinder.
8. Care should be taken to ensure that no projection of the cylinder and associated parts, can
prevent the door swinging freely.
9. All components necessary for the specific installation should be fitted.
10. The key is to be kept securely so that only authorized person may have access.
11. In case of losing a key, blocklisting of the lost key shall be done with the iLOQ Manager
software and affected locks shall be reprogrammed.
12. DECLARATION OF CONFORMITY
The products mentioned inside this user guide are in conformity with the requirements of the following
directives:
2014/53/EU Radio Equipment Directive (RED)
2011/65/EU Restriction of the use of certain hazardous substances (RoHS)
The conformity was assessed in accordance with RED module A by using the following harmonized
and other EN standards:
RED:
Art 3.1(a) Safety
EN 62368-1:2014 (2nd Ed)
EN 60065:2014 (8th Ed)
EN 60950-1:2005 (2nd Ed) + A1:2019 + A2:2013
Art 3.1(b) EMC EN
EN 301 489-1 v2.2.3
EN 301 489-3 v2.1.1
Art 3.2 Spectrum
EN 300 330 v2.1.1
RoHS
EN 50581:2012
Other standards used:
EN 15684:2020