WARNING! 

 

When working on ANY electrical equipment be sure to disconnect the unit from 

its power source to prevent any kind of electrical shock. 

 

As with any electrical appliance, do not operate any PulseBar or ionizer system 

in an area where flammable vapors, chemicals, or explosives are present. 

 

IMPORTANT 

 

All Simco equipment and power cords MUST be properly grounded to ensure 

proper operation and operator safety.

 

 
 
 

Prior to installation, insure that any outlets being used to power Simco equipment are correctly polarized 
and grounded. 
 

Section 4    Installation

 

 

The PFC can simply be placed on a benchtop or mounted vertically to a wall, workbench or machine 
using the keyhole slots on the back of the case.  The keyhole slots can also be used to secure the PFC to 
the workbench top.  The feet used on the PFC Controller are made of a durable polyurethane so that they 
will not mark benchtops or shed particles in a cleanroom environment. 

 
 

 

Figure 1.  

PFC mounting to wall 

 

The PFC Controller can be attached to almost any surface using a variety of screws and wall anchors. Check your particular 

installation to determine the type of fastener you should use. 

 

3

Содержание SIMCO PulseFlow PFC

Страница 1: ...CTIONS Operation Maintenance PFC PulseFlow Controller SIMCO s PulseFlow Controller PFC DC pulse and steady state ionizer power supply SECTION 1 Description 2 Specifications 3 Safety Procedures 4 Insta...

Страница 2: ...ne Voltage 100 120 230 VAC 50 60 Hz Output Voltage Range 3 5 kv to 8 0 kv D C Pos Neg Output Current Range 3 0 ua to 7 0 ua D C Cycle Pulse Rate Sw Pos Freq Time 10Hz 10Hz 100ms 2 2Hz 2 2Hz 450ms 1 3H...

Страница 3: ...power Simco equipment are correctly polarized and grounded Section 4 Installation The PFC can simply be placed on a benchtop or mounted vertically to a wall workbench or machine using the keyhole slo...

Страница 4: ...e PFC Connecting two PulseBars to the PFC Controller 1 Insert one HV 2 two to one Adapter into the positive output connector and one into the negative output connector located on the back panel of the...

Страница 5: ...ulse mode and will light continuously in the steady state mode 4 Select the desired Pulse Rate by rotating the Pulse Rate switch with a flatblade screwdriver from positions 10hz to 1 0hz Position SS i...

Страница 6: ...Front Panel NOTE When the PFC is first turned on one of the lamps will come on and remain on for a few moments This is normal operation After the PFC power supplies stabilize both lamps will start to...

Страница 7: ...pton Probable Solution PFC lamps do not flash or turn on at all Check that the unit is plugged in Check the fuses and replace if required The PFC lamps do not flash after a reasonable The Pulse Rate s...

Страница 8: ...ential damages except where state laws override This warranty extends to the original purchaser and is not transferable No person agent distributor dealer or company is authorized to change modify or...

Страница 9: ...9...

Отзывы: