Section 1    Description

 

 

The PulseFlow Controller incorporates both Pulse and Steady State DC technologies and is the power 
source for the PulseBar line of products.  The PulseFlow controller has four operational ranges from 
10hz to 1.0hz in pulse mode and SS for Steady State DC operation.  One PulseFlow Controller can 
power up to 20 electrode pairs of PulseBar.  The compact size of the PulseFlow Controller offers 
versatile mounting in almost any application. 

 

Section 2    Specifications

 

 

Input Power: 

4 watts 

Nominal Line Voltage: 

100 - 120 / 230 VAC 50/60 Hz. 

Output Voltage Range: 

3.5 kv. to 8.0 kv. D.C. (Pos. & Neg.) 

Output Current Range: 

3.0 ua to 7.0 ua D.C. 

  Cycle 
Pulse Rate: 

Sw. Pos. 

Freq. 

 Time

 10Hz 

10Hz 

100ms. 

 2.2Hz 

2.2Hz. 

450ms. 

 1.3Hz 

1.3Hz 

750ms. 

 1.0Hz 

1.0Hz. 

1000ms. 

 

SS 

 0Hz 

Steady State (DC) 

Temp. Range: 

+32ºF to 122ºF (0ºC to +50ºC) 

Dimensions: 

5.75” x 5.00” x 1.65” (14.60cm x 12.7cm x 4.19cm) 

Weight: 

20.5 oz (637 gr.) 

Emitter Electrodes: 

20 pairs (20 Pos. 20 Neg.) maximum. 

Fuse: 

Two 80 ma. (5x20mm) slo-blow type. 

Power Terminal: 

Meets FCC part 15J.MP-4 class B 

 

ITE Standard (VDE 0871106.78). 

EMI Radiation: 

Meets FCC part 15J.MP-4 @ 3 meters. 

 

 

Section 3    Safety Procedures 
 

 

 
 
 
 
 
 
 

 

CAUTION 

 

The maximum current available at any emitter electrode is less than 100 microamps. A person touching 

an electrode may experience a mild nuisance shock. 

 

 

 

2

Содержание SIMCO PulseFlow PFC

Страница 1: ...CTIONS Operation Maintenance PFC PulseFlow Controller SIMCO s PulseFlow Controller PFC DC pulse and steady state ionizer power supply SECTION 1 Description 2 Specifications 3 Safety Procedures 4 Insta...

Страница 2: ...ne Voltage 100 120 230 VAC 50 60 Hz Output Voltage Range 3 5 kv to 8 0 kv D C Pos Neg Output Current Range 3 0 ua to 7 0 ua D C Cycle Pulse Rate Sw Pos Freq Time 10Hz 10Hz 100ms 2 2Hz 2 2Hz 450ms 1 3H...

Страница 3: ...power Simco equipment are correctly polarized and grounded Section 4 Installation The PFC can simply be placed on a benchtop or mounted vertically to a wall workbench or machine using the keyhole slo...

Страница 4: ...e PFC Connecting two PulseBars to the PFC Controller 1 Insert one HV 2 two to one Adapter into the positive output connector and one into the negative output connector located on the back panel of the...

Страница 5: ...ulse mode and will light continuously in the steady state mode 4 Select the desired Pulse Rate by rotating the Pulse Rate switch with a flatblade screwdriver from positions 10hz to 1 0hz Position SS i...

Страница 6: ...Front Panel NOTE When the PFC is first turned on one of the lamps will come on and remain on for a few moments This is normal operation After the PFC power supplies stabilize both lamps will start to...

Страница 7: ...pton Probable Solution PFC lamps do not flash or turn on at all Check that the unit is plugged in Check the fuses and replace if required The PFC lamps do not flash after a reasonable The Pulse Rate s...

Страница 8: ...ential damages except where state laws override This warranty extends to the original purchaser and is not transferable No person agent distributor dealer or company is authorized to change modify or...

Страница 9: ...9...

Отзывы: