iLiving ILG8SF10V(APB-10A) Скачать руководство пользователя страница 7

 

1/2" 

1/2” 

1/2” 

1/2” 

1/2” 

Suggested 

Wall 

Opening(Sq) 

 

10 1/2" 

 

 

13” 

 

17” 

 

19” 

 

19” 

 

Model 

ILG8SF20V 

(APB-20A) 

ILG8SF24V 

(APB-24A) 

ILG8SF30S 

(APB-30B) 

ILG8SF36S 
(APB-36B) 

Prop.Dia 

20” 

24” 

30” 

36” 

23” 

27” 

33” 

39” 

23” 

27” 

33” 

39” 

5 3/4” 

5 3/4” 

5 3/4” 

5 3/4” 

2” 

2” 

3” 

3” 

11” 

11” 

13 3/32” 

13 11/16” 

25 21/32” 

25 21/32” 

31 5/8” 

37 21/32” 

20” 

24 1/8” 

30 1/8” 

36 5/32” 

20” 

24 1/8” 

30 1/8” 

36 5/32” 

16” 

20 1/32” 

26” 

32” 

3 17/32” 

3 17/32” 

3 17/32” 

3 17/32” 

9/32” 

9/32” 

9/32” 

9/32” 

1/2” 

1/2” 

1/2” 

1/2” 

Suggested 

Wall 

Opening(Sq) 

 

21” 

 

25” 

 

31” 

 

37” 

 
 
 

 
 
 
Model 

 
 
Prop. 
Dia 

 
 
Nom. 
HP 

 
 
 
Amps 

 
 
Nom. 
RPM 

 
 
Bearing 
Type 

 
Sones@ 
0.0”SP@ 
5” 

CFM Air 
Delivery@Static 
Pressure Shown 
0.00”  0.125”  0.25” 

ILG8SF10V 
(APB-10A) 

10" 

1/25 

0.55  1550  Sleeve 

6.19 

600 

354 

N/A 

ILG8SF12V 
(APB-12A) 

12” 

1/20 

0.60  1625  Sleeve 

5.9 

772 

418 

N/A 

ILG8SF16V 
(APB-16A) 

16” 

1/20 

0.85  1550 

Ball 

6.39 

1200 

416 

180 

ILG8SF18V 
(APB-18A) 

18" 

1/15 

0.85  1075 

Ball 

7.4 

1736  1108 

N/A 

ILG8SF18S 
(APB-18B) 

18" 

1/4 

3.50  1725 

Ball 

7.28 

3852  2836  2172 

ILG8SF20V 
(APB-20A) 

20" 

1/4 

2.75  1075 

Ball 

6.67 

3368  2312  1868 

ILG8SF24V 
(APB-24A) 

24” 

1/4 

2.75  1075 

Ball 

7.0 

4244  2676  2220 

Содержание ILG8SF10V(APB-10A)

Страница 1: ...AN Models ILG8SF10V APB 10A ILG8SF12V APB 12A ILG8SF16V APB 16A ILG8SF18V APB 18A ILG8SF18S APB 18B ILG8SF20V APB 20A ILG8SF24V APB 24A ILG8SF30S APB 30B ILG8SF36S APB 36B OWNER S MANUAL PLEASE READ A...

Страница 2: ...LL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE RETAIN INSTRUCTIONS FOR Installation troubleshooting and replacement are to be performe...

Страница 3: ...he National Electrical Code NEC and the Occupational Safety and Health Act OSHA in the United States and the Canadian Electric Code CEC in Canada 8 Always disconnect power source before working on or...

Страница 4: ...or move will result in excess vibrations which may cause possible premature motor propeller or 2 Install any auxiliary components such as thermostats switches or speed ect power to the motor using an...

Страница 5: ...5 Figure 2 Wiring Diagram Single speed 115 volt connection for ILG8SF18S APB 18B ILG8SF30S APB 30B ILG8SF36S APB 36B...

Страница 6: ...B 10A ILG8SF12V APB 12A ILG8SF16V APB 16A ILG8SF18V APB 18A ILF8SF18S APB 18B Prop Dia 10 12 16 18 18 A 13 15 18 29 32 21 21 B 13 15 18 29 32 21 21 C 4 17 32 5 3 4 5 3 4 5 3 4 5 3 4 D 2 2 2 2 2 E 5 7...

Страница 7: ...9 32 9 32 9 32 I 1 2 1 2 1 2 1 2 Suggested Wall Opening Sq 21 25 31 37 Model Prop Dia Nom HP Amps Nom RPM Bearing Type Sones 0 0 SP 5 CFM Air Delivery Static Pressure Shown 0 00 0 125 0 25 ILG8SF10V...

Страница 8: ...h air intake on the opposite side of the area to be the shutter will open automatically When the unit is turned OFF the shutter will close 4 Speed controllable units are designed to operate at a minim...

Страница 9: ...Replace fuse or reset circuit breaker Defective motor Replace motor Switch in OFF position Turn switch ON Blocked intake or exhaust opening Clear intake and exhaust openings of any obstructions Clean...

Страница 10: ...10...

Отзывы: