Inductive Source Controllers
Euro version
l
Mains Cable Access: 12 x PG16 and 1 x PG29
knockouts.
l
Control Cable Access: 1 x PG16 knockout.
SCI1220
l
Weight: 18kg
UK version
l
Mains Cable Access: 12 x 25 mm, 1 x PG29
knockouts.
l
Control Cable Access: 1 x 25 mm knockout.
Euro version
l
Mains Cable Access: 12 x PG16 and 1 x PG29
knockouts.
l
Control Cable Access: 1 x PG16 knockout.
Electrical Data
SCI0405
l
Maximum Load: 20 Amp single phase @ 40ºC.
l
Maximum Channel Current: 6 Amps.
l
Supply: 230 volts -/+ 10% 50/60 Hz.
(optionally, 127 volt 60 Hz).
l
Protection: 4 x 6 Amp MCB’s type C, 6KA rated.
SCI0410
l
Maximum Load: 40 Amp single phase @ 40ºC.
l
Maximum Channel Current: 10 Amps.
l
Supply: 230 volts -/+ 10% 50/60 Hz.
(optionally, 127 volt 60 Hz).
l
Protection: 4 x 10 Amp MCB’s type C, 6KA rated.
SCI1205
l
Maximum Load: 40 Amp single phase @ 40ºC.
l
Maximum Channel Current: 6 Amps.
l
Supply: 230 volts -/+ 10% 50/60 Hz.
(optionally, 127 volt 60 Hz).
l
Protection: 12 x 6 Amp MCB’s type C, 6KA rated.
SCI1210
l
Maximum Load: 40 Amp three phase @ 40ºC.
l
Maximum Channel Current: 10 Amps.
l
Supply: 415/230 volts -/+ 10% 50/60 Hz.
(optionally, 220/127 volt 60 Hz).
l
Protection: 12 x 10 Amp MCB’s type C, 6KA rated.
SCI1220
l
Maximum Load: 63 Amp three phase @ 40ºC.
l
Maximum Channel Current: 20 Amps.
l
Supply: 415/230 volts -/+ 10% 50/60 Hz.
(optionally, 220/127 volt 60 Hz).
l
Protection: 12 x 20 Amp MCB’s type C, 6KA rated.
Load Types
l
Incandescent 230 volt lamps.
l
Inductive Wire wound (allow for 10% transformer
losses).
l
Leading edge electronic transformers.
l
Cold Cathode (Check the iLight™ help desk for details).
Minimum Load
l
20 watts per channel.
Dimmed Outputs
SCI0405, SCI0410
l
4 x 40 Amp rated Triacs.
SCI1205, SCI1210, SCI1220
l
12 x 40 Amp Triacs.
Switched Outputs
l
The Dimmed outputs may be configured as switches,
for non-dimmed loads. They require a minimum load
of 30mA for them to latch. Before connecting
Discharge lamps, consult with the iLight™ help desk.
Terminal Sizes
l
Incoming supply, maximum cable size: 10mm2.
SCI0405S - Single pole
SCI0405N - Neutral disconnect
SCI0410S - Single pole
SCI0410N - Neutral disconnect
SCI0410D - Double pole
SCI1205S - Single pole
SCI1205N - Neutral disconnect
SCI1210S - Single pole
SCI1210N - Neutral disconnect
SCI1210D - Double pole
SCI1220S - Single pole
SCI1220N - Neutral disconnect
SCI1220D - Double pole
Common specifications as detailed on
page 12 plus the following
:
Key Features
SCI0405
l
- 4 x 5 Amp fully rated Source Controller.
SCI0410
l
- 4 x 10 Amp fully rated Source Controller.
SCI1205
l
- 12 x 5 Amp fully rated Source Controller.
SCI1210
l
- 12 x 10 Amp fully rated Source Controller.
SCI1220
l
- 12 x 20 Amp Source Controller.
l
Dims resistive, inductive and low voltage electronic
transformer loads (That are compatible with leading
edge dimmers).
l
Quiet operation.
Mechanical Data
SCI0405
l
Weight: 4kg.
l
Mains Cable Access: 4 x 25 mm, 4 x PG16 and 1 x
PG21knockouts.
l
Control Cable Access: 1 x 25 mm, 1 x PG16
knockouts.
SCI0410
l
Weight: 7kg.
l
Mains Cable Access: 4 x 25 mm, 4 x PG16 and 1 x
PG21knockouts.
l
Control Cable Access: 1 x 25 mm, 1 x PG16
knockouts.
SCI1205
l
Weight: 10kg.
UK version
l
Mains Cable Access: 12 x 25 mm, 1 x PG29
knockouts.
l
Control Cable Access: 1 x 25 mm knockout.
Euro version
l
Mains Cable Access: 12 x PG16 and 1 x PG29
knockouts.
l
Control Cable Access: 1 x PG16 knockout.
SCI1210
l
Weight: 18kg.
UK version
l
Mains Cable Access: 12 x 25 mm, 1 x PG29
knockouts.
l
Control Cable Access: 1 x 25 mm knockout.
13 of 23
INTELLIGENT CONTROLS
Содержание SCI0405
Страница 2: ......
Страница 3: ...2 of 23 INTELLIGENT CONTROLS ...
Страница 12: ...General Specifications 11 of 23 INTELLIGENT CONTROLS ...
Страница 21: ...Adaptive Source Controllers 20 of 23 SCA1210S INTELLIGENT CONTROLS ...