![IKL GULIVER TERMO Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/ikl/guliver-termo/guliver-termo_user-manual_2042869007.webp)
If you want smoke exaust from the back side, unscrew the screws that bind the drain
cover and back of the stove, and place with the screws fix the drain plug on that place.
Cover bolts connect with the frame of the stove on the appropriate place.Make sure that
gaskets that are on the cover and on the connector are in the channels and tightened
sufficiently to prevent the passage of smoke. Cover on the top of the stove, which is closer to
the combustion chamber, do not removable (item 27).
The gallery is supplied with the stove, but is not
instaled.Instalation is with the screws as shown in picture
(Picture.2).
Note:
To move the stove never use the gallery because it is
not its function and may break the holder of the gallery
which are made of cast iron.
Picture.2
Picture.3
Connect the boiler to install central heating
Thermo Gulliver has a boiler with heat
exchanger tube made of quality boiler steel.
Connections for the water are pipes of 1 “, made
from the same material.
The product is intended for heating of
residential premises, and food preparation.
For water supply and drainage into the system
of storey (central) heating is provided with the
connections on the boiler - 1 “. Storey stove can
be installed into indoor or outdoor central heating
system, as shown in pictures 4, 5 and 6. For a
closed system there two modes of binding,
depending on the position of the pump.
An integral part of the installation for thermal discharge valve that serves as termofuse
from possible overheating. It is recommended valve for heat discharge Caleffi 544 1/2 shown in
Picture 3.
Thermal discharge valve with a double effect, brilliantly solves the security problems in
heating installations which as a source of heat use furnaces , solid fuel stoves and
fireplaces. It is a device which has a valve for the heat discharge and drain valve for filling
that act simultaneously on command ofremote sensors. A device that is connected to the
outlet and the power supply (battery charger) when achieve the critical temperature,
creates a circulation of cold water in the boiler until the temperature drops below the value
at which reacts sensitive element. At that point, at the same time is closing of outlet
Содержание GULIVER TERMO
Страница 4: ......
Страница 9: ...Picture 4 Schemeofclosedsystem...
Страница 10: ...Picture 5 Schemeofclosedsystem...
Страница 11: ...Picture 6 Schemeofopensystem...
Страница 20: ......
Страница 21: ......