IKL GULIVER TERMO Скачать руководство пользователя страница 15

Regulation of the draft

Picture 9

Combustion rate and thus the amount of heat

which gives the stove, depends on the amount of
combustion  air   that  is  brought  into  the  space
below  grill.  Regulation  of  the  amount  of  air  is
achieved  automatically   through   the   controller   of
draft  Rathgeber  placed  on  the  back  of  the  stove
(Picture 9), or manually, by turning of the button on
the stove frame connected with the draft regulator
(Picture 1 position 28).

Button turns with extra accessories and has two extreme positions:

1. Turning to the final position in the direction shown in 

picture.10. gives a maximum draft;

Right cooker stove

Left

cooker stove 

Picture 10

Close

Close

Picture 11

2.

Turning to the end position opposite of the

direction shown in picture.10, gives a minimum draft;

Primary  air  regulator  (position.20)  is  set  in  the

closed position and it should be kept in this position at
all  times  of  work  of  the  stove.  When  closed,  the
regulator prevents air intake from the front side below
the the grille, which automatically regulates the intensity
of burning by draft regulator, located on the back side
of the stove. If for some reason burning is difficult, due
to   weather   conditions  or   high  humidity  fuels  (wood,
coal),  the  controller  of   the  primary  air  can
open(Picture.11).

NOTE: If the primary air regulator is open, the air flow is steady, so that can lead 
to the overheat the water in the system.

Regulation of the secondary air

             

The secondary air regulator should be put in

Close

Open 

Picture 12

 

the  position  closed  during  ignition  and    held  in  that

position  until you  establish   the operation heating regime.
After  that,    put  theregulator  into  the  position  opened  and
hold it in that position during the stove is in operation. The
secondary air is used to clean

Содержание GULIVER TERMO

Страница 1: ...1 Model GULIVER TERMO USER MANUAL IKL INDUSTRIJSKI KOMBINAT LIVNICA DOO GU A Srbija 32230 Gu a Albanske spomenice bb Tel centrala 381 0 32 306 000 prodaja i servis 381 0 32 854 305...

Страница 2: ...ossibilities before first operating it and keep them for future reference to ensure avoiding irregularities in your stove s operation Yours sincerely GU A CONTENTS 1 Introductory notes 2 Technical dat...

Страница 3: ...or should be opened only to add fuel Open door gradually to equalise internal pressure Opening the doors suddenly may cause flame and smoke to escape outside Fuel should be added only when glowing emb...

Страница 4: ......

Страница 5: ...bar 2 Rated output kg h 3 6 Boiler capacity l 15 Efficiency 88 Flue pipe diameter mm 120 150 Heat capacity m3 190 250 The mean content of CO at 13 O2 0 1007 Weight kg 190kg Firebox opening size width...

Страница 6: ...primary air Stove is connected to the chimney flue pipe appropriate to ensure adequate tightness and flow of smoke from the stove to chimney Flue pipe must not be too deep in the chimney so it would...

Страница 7: ...ended for heating of residential premises and food preparation For water supply and drainage into the system of storey central heating is provided with the connections on the boiler 1 Storey stove can...

Страница 8: ...highest radiator Note The installation and commissioning of the entire system should be entrusted only technician who ensures proper operation of the entire heating system In the case of poorly design...

Страница 9: ...Picture 4 Schemeofclosedsystem...

Страница 10: ...Picture 5 Schemeofclosedsystem...

Страница 11: ...Picture 6 Schemeofopensystem...

Страница 12: ...ught in the flue the chimney must be rising at least one metre above the ridge of the roof The chimney must not be covered by surrounding objects Picture 4 Picture 4 The dimensions of the chimney may...

Страница 13: ...gulator into the open position open the hearth door put the necessary fuel into the hearth ungreased paper small pieces of wood Ignition is performed The hearth and ashtray door is closed After the in...

Страница 14: ...the exit of smoke and flame from the hearth The hearth door must be closed when the stove is used Picture 8 The wood should have maximum 20 humidity In addition to bad combustion effect wet wood leav...

Страница 15: ...mary air regulator position 20 is set in the closed position and it should be kept in this position at all times of work of the stove When closed the regulator prevents air intake from the front side...

Страница 16: ...glass surface After cleaning rinse with pure water and dry The additional equipment that is delivered with the stove is the glove and equipment for shaking of embers and removal of ashtray picture13 P...

Страница 17: ...tor for primary air Frame of the top plate all doors grill furnace linings grill smoke exhaust port and galleries cariers were made of gray cast iron On the oven door and fireplace is the glass temper...

Страница 18: ...equately Check whether the chimney dimensions are correct and suitable for the device Check the thermic insulation of the chimney and if it is made according to standard The hearth door must be closed...

Страница 19: ...ove loses the right for the service provided by the manufacturer s warranty The supply of spare parts is performed exclusively through the factory service based on the positions and pictures in this i...

Страница 20: ......

Страница 21: ......

Отзывы: