IKL GULIVER TERMO Скачать руководство пользователя страница 13

5. LIGHTING

Prior to the first stove lighting, it is necessary to wipe all stove surfaces with a dry cloth,

remove dust, oil and impurities from the stove plate and the oven in order to avoid their
combustion and uccurence of unpleasant odours and smoke.

The  first  time  that  the  appliance  is  lit,  there  will  be  an  unpleasant  odour  and  smoke

given off, especially from the stove plate surface, as well as from the other parts protected with
a  heat  resistant  paint.  This  is  a  normal  occurrence  because  the  paint  stabilizes  on
temperatures above 250°C during the first lighting.  A good ventilation of the room where the
stove is located must be ensured.

The ignition is performed in the following manner:

• The  handle  of  the  regulator  of  the  gases  flow  should  be  pulled  towards  you,  thus

enabling the smoke flow towards the chimney via the shortest route.

•Position the primary air regulator into the open position,
•open the hearth door,
•put the necessary fuel into the hearth (ungreased paper, small pieces of wood),
•Ignition is performed,
•The hearth and ashtray door is closed,

After  the  initial  flame,  wider  wood  logs  should  be  put  into  the  hearth,  the

hearth door  is  closed,  the  draft  is  reduced  to  half,  and  the  regulator  handle  is  positioned
into the front position (Image 5).

IMPORTANT:  When  opening  the  stove  door,  due  to  high  temperatures  on  the
stove  handles,  you  must  use  the  protective  glove  which  is  delivered  with  the
stove.

Fuels like petrol or light distillate oil and similar fuels must not be used, because they can

lead to stove damaging and explosion.

Among  the  others,  the  following  cannot  be  burnt:  organic  waste,  food  leftovers,  used and

painted  wood,  plastic  objects,  flammable  and  explosive  materials  the  combustion  of  which
disturbs proper operation of the stove and can cause damage and environment pollution.

High  outside  temperatures  may  cause  bad  airflow  (draft)  in  the  chimney,  so  it  is

recommended to put smaller quantities of fuel more frequently.

Содержание GULIVER TERMO

Страница 1: ...1 Model GULIVER TERMO USER MANUAL IKL INDUSTRIJSKI KOMBINAT LIVNICA DOO GU A Srbija 32230 Gu a Albanske spomenice bb Tel centrala 381 0 32 306 000 prodaja i servis 381 0 32 854 305...

Страница 2: ...ossibilities before first operating it and keep them for future reference to ensure avoiding irregularities in your stove s operation Yours sincerely GU A CONTENTS 1 Introductory notes 2 Technical dat...

Страница 3: ...or should be opened only to add fuel Open door gradually to equalise internal pressure Opening the doors suddenly may cause flame and smoke to escape outside Fuel should be added only when glowing emb...

Страница 4: ......

Страница 5: ...bar 2 Rated output kg h 3 6 Boiler capacity l 15 Efficiency 88 Flue pipe diameter mm 120 150 Heat capacity m3 190 250 The mean content of CO at 13 O2 0 1007 Weight kg 190kg Firebox opening size width...

Страница 6: ...primary air Stove is connected to the chimney flue pipe appropriate to ensure adequate tightness and flow of smoke from the stove to chimney Flue pipe must not be too deep in the chimney so it would...

Страница 7: ...ended for heating of residential premises and food preparation For water supply and drainage into the system of storey central heating is provided with the connections on the boiler 1 Storey stove can...

Страница 8: ...highest radiator Note The installation and commissioning of the entire system should be entrusted only technician who ensures proper operation of the entire heating system In the case of poorly design...

Страница 9: ...Picture 4 Schemeofclosedsystem...

Страница 10: ...Picture 5 Schemeofclosedsystem...

Страница 11: ...Picture 6 Schemeofopensystem...

Страница 12: ...ught in the flue the chimney must be rising at least one metre above the ridge of the roof The chimney must not be covered by surrounding objects Picture 4 Picture 4 The dimensions of the chimney may...

Страница 13: ...gulator into the open position open the hearth door put the necessary fuel into the hearth ungreased paper small pieces of wood Ignition is performed The hearth and ashtray door is closed After the in...

Страница 14: ...the exit of smoke and flame from the hearth The hearth door must be closed when the stove is used Picture 8 The wood should have maximum 20 humidity In addition to bad combustion effect wet wood leav...

Страница 15: ...mary air regulator position 20 is set in the closed position and it should be kept in this position at all times of work of the stove When closed the regulator prevents air intake from the front side...

Страница 16: ...glass surface After cleaning rinse with pure water and dry The additional equipment that is delivered with the stove is the glove and equipment for shaking of embers and removal of ashtray picture13 P...

Страница 17: ...tor for primary air Frame of the top plate all doors grill furnace linings grill smoke exhaust port and galleries cariers were made of gray cast iron On the oven door and fireplace is the glass temper...

Страница 18: ...equately Check whether the chimney dimensions are correct and suitable for the device Check the thermic insulation of the chimney and if it is made according to standard The hearth door must be closed...

Страница 19: ...ove loses the right for the service provided by the manufacturer s warranty The supply of spare parts is performed exclusively through the factory service based on the positions and pictures in this i...

Страница 20: ......

Страница 21: ......

Отзывы: