background image

 - 

 

 

IKENO INDUSTRIAL DEHUMIDIFIER - USER'S MANUAL -  Model ID-series 

Subject to change without prior notice 

III. INSTALLATION 
 
1. Receiving inspection 
Remove the shipment packing and inspect unit  to  ensure  that  no  damage  has  occurred 
during transportation and storage. Any visible damage must be reported to nearest Ikeno 
representative.  
 
2. Working Environment 
+  The unit should be installed stably. There should be one meter of space in front of the 

inflow and outflow. There should be no large obstacle around it. 
+   The machine set should be far from heat source and inflammable gas. 
+   The condensed water could be drained out of the room or into a pail. 
+   It is advisable to not to install it in a place of heavy dust or serious pollution. 
 
3. Power source 
+  The power should be supplied with a special wire.  
+  Provide automatic circuit breaker.  
+  There should be reliable electrical grounding. 
 
4. Other requirement 

+  Skilled professional personnel should perform maintenance of the unit. 
+  Parking inclination of the unit should not exceed 10

o

 
IV. OPERATION PROCEDURES 
 
 
 
 
 
 
 
 
 
 
 
 
 

1. Turn on 
 
+ Switch on the main insulator (provided by contractor).  
+ The power lamp (2) is on.  
+ Turn humidistat knob (5) to desired value 
+ Push ON button (3) to start the unit (Notice: in case the 
unit has just been stopped for less than 3 minute, the delay 
relay keeps the turn on for 3 minutes to protect 
compressor).  
+ The Operation lamp (1) is on and unit starts working.  
 
2. Turn off 
 
+ Push OFF button (4) to turn the unit off.  
+ Switch off main insulator 
 
Notice !: Vapor pressure gauge (6) used to check 
compressor performance (technical personal only).  
 

 
V. MAINTENANCE 
 
* Switch off the power source before maintenance.  
 
* Due to the accumulation of dusts, the air filter should be cleaned to avoid effecting 
dehumidifying and going wrong periodically, at least once a month.  
 

 

Содержание ID-3750

Страница 1: ...IKENO DEHUMIDIFIER Model ID 3750 Standard type USER S MANUAL...

Страница 2: ...1 MAIN FEATURES 2 2 COMPONENT IDENTIFICATION 3 3 WORKING PRINCIPLE 3 4 DIMENSION 4 5 SPECIFICATION 5 6 MOISTURE REMOVAL CAPACITY 5 7 ELECTRICAL DIAGRAM 6 III INSTALLATION 1 RECEIVING INSPECTION 7 2 WO...

Страница 3: ...n Model ID series designed by our company is the most reliable unit in the range It dehumidifies air by dropping air temperature below its dew point to condensate out moisture vapor The condensation w...

Страница 4: ...cumulator magnetic flow control valve evaporator coil condenser coil capillary tube centrifugal fan temperature sensor humidity sensor and electrical wiring The centrifugal fan makes wet air entering...

Страница 5: ...er defrosting the dehumidifier will turn back to run normally In order to protect the unit from severe damage during operation the unit is equipped with such a safety features such as low pressure cut...

Страница 6: ...ithout prior notice 5 SPECIFICATION STANDARD MODEL Type ID 3750 Capacity L h 13 Flow m3 h 3000 Power Kw 5 5 Note Nominal working condition 27 0o C DB 21 2o C WB Low temperature working condition 5 0o...

Страница 7: ...R USER S MANUAL Model ID series Subject to change without prior notice 7 ELECTRICAL DIAGRAM COMP Compressor TR1 Time relay 3 min TR2 Time relay 30 min LTP Low pressure switch HTP High pressure switch...

Страница 8: ...re Provide automatic circuit breaker There should be reliable electrical grounding 4 Other requirement Skilled professional personnel should perform maintenance of the unit Parking inclination of the...

Страница 9: ...the pipe VII POINTS TO REMEMBER 1 Its outlet dry air temperature is higher than inlet air temperature but outlet air s moisture content is lower When the dried air is sent to one space it soon will m...

Страница 10: ...ct The running direction of fan wheel points to machine s fron face 14 Adjust humidity controller set one required humidity value 15 Press ON button to start Fan 16 The compressor will start after 3 m...

Страница 11: ...or use which is contrary to the instructions given in this manual can cause personal injury and or machine damage Warranty and obligations The warranty period is 12 months from commissioning date unle...

Страница 12: ...Assembled in Thailand...