background image

9

LI-ION BATTERY PACK 4067 

(continued)

CHARGING THE BATTERY PACK

Requires Ikelite 4067.1 Smart Charger Li-ion. 

Do not 

attempt to charge the battery pack

with other chargers. Use of an incompatible charger is a safety risk and may cause
irreparable damage to the battery pack.

Typical recharge time is approximately 5 hours.

STORAGE

Do not store a depleted battery pack for extended periods of time. Charge the battery
pack to at least half full prior to storing. Always place the power switch in the locked OFF
position. Store in a cool, dry place. We suggest storage of your strobe with the locking
lever OPEN to allow any hydrogen/air mixture to escape.

WARNINGS

- Always turn off and lock the battery power switch or disconnect the battery and store in

a cool, dry place when not in use.

- The battery pack is not waterproof when removed from the strobe. 
- Do not disassemble the battery pack.
- Do not expose the pack to heat.
- Do not use lubricant, cleaners, or any chemical on the o-ring or battery pack.
- NEVER use or charge a water damaged battery pack. Flooding may cause a short    

circuit and lead to overheating.

- Do not discard, crush or incinerate. Check local rules and regulations on electronic 

waste disposal and use an approved recycling facility.

- Do not ship or travel with a flooded or known defective battery pack.

USING NIMH OR NI-CAD BATTERY PACKS

The DS161 Substrobe head also accepts both 4066.5 NiMH battery packs and 4066
Ni-Cad battery packs in good working condition. Do not use a battery pack with dead or
water damaged cells. If you intend to use an older battery pack on your new Substrobe,
please reference the notice dated 6/22/09 on the following web page:

http://www.ikelite.com/web_pages/important.html.

Содержание 4061.1 DS161

Страница 1: ...Please read all instructions before using this product I n s t r u c t i o n M a n u a l 4061 1 DS161 Substrobe...

Страница 2: ...Diffuser Installation and Removal 11 ARM SYSTEMS STROBE MOUNTS 12 Ikelite Arm Systems 12 Ikelite Mounts 12 STROBE CONNECTION 13 Strobe Connection Illustration 14 USING AS HARD WIRED STROBE 15 USING A...

Страница 3: ...gy Rating 160 watt sec Recycle Time 1 4 sec Angle of Coverage 90 degrees 100 degrees with diffuser Guide ISO 100 feet 76 surface 38 underwater Guide meters 24 surface 12 underwater Color Temperature 4...

Страница 4: ...as as well as all older TTL film cameras including the Nikonos system A variety of sync cords sensors and TTL adapters are available to connect to almost any camera system currently on the market STRO...

Страница 5: ...gauge references the remaining battery capacity Aim the DS161 and illuminate your subject s colors with the built in modeling light night diving light movie light OVERVIEW OF DS161 FEATURES Separate p...

Страница 6: ...ater contact with the battery pins Damage corrosion can cause a short circuit O RING The o ring is located on the inside rim of the battery pack Keep the o ring and the sealing surfaces clean DO NOT s...

Страница 7: ...7 OPEN R C D INDPLS IN U S A UNLOCK INDPLS IN U S A UNLOCK Pull Out Flip Up Rotate OPENING AND CLOSING illustration...

Страница 8: ...ter Additional battery packs are available through an Ikelite dealer The battery pack does NOT remain waterproof when removed from the strobe Therefore we suggest keeping the open portion of the batte...

Страница 9: ...l dry place when not in use The battery pack is not waterproof when removed from the strobe Do not disassemble the battery pack Do not expose the pack to heat Do not use lubricant cleaners or any chem...

Страница 10: ...ithium Ion Battery Pack Input 100 240 Volts AC 50 60 Hertz 0 6 Amps Output 8 4 Volts Operating Temperature 32 F 104 F 0 C 40 C Storage Temperature 4 F 185 F 20 C 85 C Smart Charger Li ion with US plug...

Страница 11: ...er Retention Tabs 2 Press down lightly until the diffuser is flush against the strobe face 3 Rotate the Diffuser Installation Posts either direction until the Posts stop against the strobe s Diffuser...

Страница 12: ...of the strobe The mount slides into the strobe base and is secured with a screw supplied with optional mount Make sure to slide the mount into the strobe base until it stops Be careful to not cross t...

Страница 13: ...ON TO STROBE To connect either a sync cord or sensor to the DS161 Substrobe follow these instructions 1 Turn the substrobe to OFF and make sure all components are dry Clean and lightly lubricate the s...

Страница 14: ...14 STROBE CONNECTION illustration Bulkhead Connection Retaining Ring Stem O ring Blue Band 4103 51 Ikelite Sync Cord DS161 Substrobe Bulkhead Cap...

Страница 15: ...r manual exposure modes TTL thru the lens exposure automatically compensates for aperture distance and filters Because there s such a wide range of apertures and subject distances photographers wantin...

Страница 16: ...the Substrobe s Firing Mode switch The light emits 100 power in the Full switch position Brightness is reduced for each subsequent position of the switch down to 50 power at the 4 5 position With the...

Страница 17: ...away from the switch Always turn the Substrobe OFF before opening the strobe ON There are two ON positions Rotating the switch clockwise to the first ON position turns on the power to the Substrobe F...

Страница 18: ...2 2 1 2 3 3 1 2 4 4 1 2 TTL Auto Thru The Lens Auto Exposure The camera automatically signals the strobe to turn off when the exposure is correct The camera must feature compatible TTL Auto exposure t...

Страница 19: ...is fully powered and ready to fire If the strobe ready light does not glow red the batteries may be expended Your camera s ready light lightning bolt in the camera viewfinder may blink while the DS161...

Страница 20: ...ound a wider aperture lightens it Add a second DS161 Substrobe for more natural looking photos and wider angle of coverage when shooting both still and video images Add a second Substrobe using either...

Страница 21: ...tretch the o ring when cleaning It is not necessary to lubricate the o ring Never use spray lubricant because it may crack the plastic 5 Keep the strobe bulkhead connector threads clean and lightly lu...

Страница 22: ...y damage the DS161 s electronics The specific receptacles to connect with the paper clip vary based on the type of cord you own Please refer to the diagram of two types of flash cord contacts Ikelite...

Страница 23: ...ase The DS161 Li ion Battery Pack is warranted against any manufacturing defects for a period of one 1 year from the original date of purchase All other claims of any nature are not covered Except as...

Страница 24: ...e visit www ikelite com to register your Ikelite Digital Substrobe within 15 days of purchase Ikelite Underwater Systems 50 West 33rd Street Indianapolis IN 46208 USA www ikelite com PRODUCT REGISTRAT...

Отзывы: