5. SPECIFICATIONS
5.1 Rating
(1) Power Supply
Voltage
: DC +11 to +16 V rating DC +12 V
Wattage
: Approx. 3.2 W
(2) Dimensions and Weight
Dimensions
: 92.2 mm (Width) x 177.5 mm (Height) x 355.5 mm (Depth)
Weight
:
Approx.
2.1kg
5.2 Control
Conditions
●
Analog Controls
- RGBM GAIN
- RGBM FLARE
- MASTER GAMMA
- RGBM PEDESTAL
- DTL LEVEL
- KNEE POINT
- KNEE SLOPE
- COLOR SATURATION
- IRIS
- SHUTTER SPEED
- VAR C.TEMP
- F KEY (SKIN DTL GAIN, Hi-Light DTL GAIN)
●
ON/OFF Controls
- BARS
- CAL
- COLOR TEMP
- SHUTTER
- VARIABLE SHUTTER
- BLACK STR / PRESS
- GAMMA
- MASTER GAIN
- FILTER (ND, CC, EFF)
- SOFT DTL
- SKIN DTL
- COLOR SATURATION
- AUTO KNEE
- AUTO IRIS
- CALL
- COLOR LINK
- MASTER (When COLOR LINK switch is turn to “ON“.)
- BLACK GAMMA
- CUSTOM COLOR
- COLOR CORR
-
MATRIX
-
SUPER
KNEE
- F KEY (Gamma Mode, DTL, Knee, Flare, Hi-Light DTL, Smooth Knee, AWB ch, ATW, Digital Extender, AVC)
●
Automatic Functions
-
AWB
-
ABB
-
AUTO
SETUP
- KNEE
- IRIS
- ENG FILE
5.3 Environmental
Conditions
(1) Operating Conditions
Temperature
: 0 to +45
℃
Humidity
: 30% to 90% (Non condensation)
(2) Storage Temperature
Temperature
: -20 to +60
℃
(3) Earthquake Resistance
Operating
: 10 to 57 Hz
0.3 mmp-p amplitude
: 57 to 150 Hz
19.6133 m / S2 (2G)
The test is conducted once for each of X, Y, and Z axes with 1 octave (i.e., 57 to 150 Hz) in 1 minute.
(4) EMI
FCC
class
A
5. SPECIFICATIONS
5-1
OCP-100 1209 VOL1 (U) (E)
OCP-100
Содержание OCP-100
Страница 2: ......
Страница 8: ...OCP 100 OCP 100 1209 VOL1 U E iv CONTENTS ...
Страница 16: ...1 8 1 NAME and FUNCTION OCP 100 OCP 100 1209 VOL1 U E ...
Страница 36: ...3 16 3 OPERATION OCP 100 OCP 100 1209 VOL1 U E ...
Страница 38: ...4 2 4 TROUBLESHOOTING OCP 100 OCP 100 1209 VOL1 U E ...
Страница 40: ...5 2 5 SPECIFICATIONS OCP 100 OCP 100 1209 VOL1 U E ...
Страница 42: ......
Страница 44: ......
Страница 45: ......