14
①
Infrared sensor
Infrared sensor for the optional wireless remote controller
RCT-30A
.
②
NO BURST LED
LED which operates only when the composite signal input is selected.
The LED lights up when the selected composite signal has no burst (black and white
signal) or when the color killer circuit is activated.
③
OVERLOAD LED
This LED lights up when the ABL circuit is activated (the luminance is higher than
necessary).
Using the monitor in a way which causes this LED to light up continuously for a long
time will deteriorate the CRT. Therefore use the monitor with the luminance lowered.
④
DEGAUSS switch
When the power is turned ON, CRT demagnetization will be performed automatically.
This switch allows demagnetization to be performed at one-touch.
As pressing this switch continuously has no effect, release and press again 2 to 3
minutes later.
⑤
POWER switch, LED
Switch for turning the monitor power ON/OFF. The LED is ON when the power is turned ON.
Always turn ON the
MAIN POWER switch
on the rear panel when starting the monitor.
Normally turn ON/OFF using this switch.
WARNING
POWER
DEGAUSS
OVER LOAD
NO BURST
⑤
④
②
③
①
4. User Adjustment
4-1. Power Supply
FUSE
6.25A250V
AC IN
AC100-120V
MAIN
POWER
①
FUSE
Fuse for preventing over-current.
When the fuse is blown, replace it with a rated 6.25A (250V) slow-blow fuse after
eliminating the cause.
②
MAIN POWER switch
To operate the monitor, turn ON this MAIN POWER switch as well as the POWER
s
witch on the front panel.
③
AC power input
Insert the provided AC cable here to supply AC power.
④
Lock
After inserting the AC plug, lock the AC plug with this lock to prevent it from disconnecting.
Fig. 4-1.
POWER Section on Rear Panel
4-2. Names and Functions of Front Left Panel Parts
Fig. 4-2 Front Left Panel