5 - 36
5. OPERATION
NEXT PAGE
INTERFACE
COMMAND MODE
COMMAND/PC
ISCP LOG
(It is displayed only
when ISCP is selected
with the COMMAND
MODE.)
EXIT
-
-
-
-
QUIT
RESET LOG
COMM LOG
LOG RUN
-
-
422, SINGLE
ICCP, ISCP
(1200/2400/4800
/9600/19200)
COMMAND, PC
-
ON, OFF
0
to
82
START, STOP
-
-
422
ICCP
COMMAND
-
-
0
START
-
Moves to ENGINEER PAGE3.
Switches I/O interfaces of the REMOTE connector.
422 : balanced RS-422 level, SINGLE : unbalanced TTL level
Switches communication protocols of the REMOTE connector.
ICCP : Standard remote controller protocol in two-way handshaking
mode.
ISCP : Remote control protocol in one-way or two-way handshaking
mode. Baud rate is set according to the communication speed.
COMMAND : Mode for connecting standard remote controller.
PC : Mode for adjusting. It is not used usually.
Moves from the sub menu to the main menu.
OFF : Saves the received data log.
ON : When it is set to ON, data is reset to 0 by selecting EXE.
Received data log of ISCP command is displayed by selecting
“
COMM
LOG.
”
And the data up to 100 can be confirmed by changing the numerical value.
START : Saves the received data to the log.
STOP : Does not save the received data to the log.
Turns off the menu.
MAIN MENU
SELECT
SUB MENU
FUNCTION
****** ENGINEER PAGE2 ******
DEFAULT
CAUTION
W h e n I S C P i s s e l e c t e d w i t h t h e C O M M A N D M O D E , t h e u s u a l
r e m o t e c o n t r o l l e r c a n n o t b e c o n n e c t e d . A t t h i s t i m e , t h e m e n u
operation becomes impossible. In this case, please operate the
menu switch of CCU to return it to ISCP.
NEXT PAGE
IRIS CIRCUIT ADJUST
FILTER SETUP
ND FILE SETUP MODE
SINGLE FILTER MODE
BLK SET REF
ENGINEER SET FILE
RENEW
PROGRAM UPDATE
EXIT
-
QUIT
ADJUST MODE
QUIT
POSITION ADJUST
-
-
QUIT
R BLK REF
G BLK REF
B BLK REF
QUIT
DATA RENEW
MODE
CAMERA ROM
-
-
-
-
-
ON, OFF
ON, OFF
ON, OFF
-
-100 to +100
-100 to +100
-100 to +100
-
-
READY, CANCEL,
EXECUTE
-
-
-
-
-
OFF
OFF
OFF
-
-4
-4
-4
-
-
-
-
Moves to ENGINEER PAGE4.
Moves from the sub menu to the main menu.
Adjusts the relationship between the fixed iris value and the answer value.
Moves from the sub menu to the main menu.
When it is set to ON, impresses the voltage to filter servo forcibly.
Creates ND FILE when set to ON, and AWB is executed at each ND
filter position.
When it is set to ON, operates as same as the filter structure of 1
:
through, 2
:
5600k, 3
:
5600k+1/4ND, 4
:
5600k+1/64ND at the CC filter
command.
Moves from the sub menu to the main menu.
R ch correction value
G ch correction value
B ch correction value
Moves from the sub menu to the main menu.
Saves the camera level adjustments and menu item settings. The saved
data can be read as user-set data through “PRESET FILE LOAD” of
MENU PAGE6.
Updates the program software of the camera.
Operates while connecting the remote controller (RCP-50B, etc.) with a
memory card slot.
Turns off the menu.
MAIN MENU
SELECT
SUB MENU
FUNCTION
****** ENGINEER PAGE3 ******
DEFAULT
Содержание HDL-45E