[AWB CC CONTROL]
Sets the mode for which the ECC
fi
lter is automatically switched when AWB is performed.
・
ON : The ECC
fi
lter is automatically switched.
・
OFF : The ECC
fi
lter is not automatically switched.
AWB CC CONTROL is the function to perform AWB again by switching the ECC filter automatically when the color
temperature of the subject does not fit with the ECC filter position of the camera
.
This enables to adjust the white
balance within all the color temperature ranges with one operation of AWB
.
Auto Peak Shading is the function to adjust the black level on the edge of the screen automatically
.
It takes several
minutes to complete APS
.
■
AUTO IRIS SET
IRIS SET MODE
:
ON
:
Enables the adjustment of AUTO IRIS
.
OFF
:
Prohibits the adjustment of AUTO IRIS
.
IRIS LEVEL SET
:
Adjusts the video level where AUTO IRIS converges
.
PEAK RATIO SET
:
Adjusts the AUTO IRIS response
.
The larger the value is, the more sensitive to a small light
source the camera gets
.
IRIS GAIN
:
Adjusts the sensitivity of AUTO IRIS
.
IRIS SPEED
:
Adjusts the operation speed of AUTO IRIS
.
IRIS LIMIT
:
Select a limit value of the iris that can be closed by AUTO IRIS
.
The iris can be closed up to the F
value to be selected
.
LENS ADJUST
:
Used to adjust the combination with lenses
.
Normally, this item is not used
.
■
MANUAL DPC
DPC
:
ON
:
Goes to defective pixel correction ON condition
.
OFF
:
Goes to defective pixel correction OFF condition
.
MANUAL DPC
:
Carries out defective pixel correction
.
DPC EFFECT CHK
:
OK
:
Possible to confirm correction condition of scratch within setting range
.
CANCEL
:
Cancels execution of confirmation of scratch correction condition
.
DPC CLEAR
:
OK
:
Erases all correction data for defective pixel correction
.
CANCEL
:
Cancels execution of erasure of defective pixel correction data
.
AUTO SETUP MODE
QUIT
IRIS SET MODE
OFF
IRIS LEVEL SET
+10
PEAK RATIO SET
+10
IRIS GAIN
75
IRIS SPEED
50
IRIS LIMIT
F22
LENS ADJUST
OFF
(
OFF, ON
)
(
-100
〜
+100
)
(
-100
〜
+100
)
(
0
〜
100
)
(
0
〜
100
)
(
F22, F20, F18, F16
)
(
OFF, ON
)
MANUAL DPC
QUIT
DPC
OK
MANUAL DPC
DPC EFFECT CHK
OK
DPC CLEAR
OK