86
i
■
MENU (3/4)
Menu Item
Initial
Setting
Setting Value
Description, Remarks
MENU DATA
ALL
VF
SCAN FORMAT SELECT
SCAN MODE
Destination
setting
1080I59, 720P59,
1080I50, 720P50
Selects the camera operation format.
* If BS/CCU is connected, the format on the BS/CCU side
and the operation format will be the same.
×
×
CPU SYSTEM CONTROL
―
SEMI SELF MODE
ON
ON, OFF
21 :LOOKROGVHWWLQJVPDGHE\WKHRSHUDWLRQFRQWURO
panel when the panel is disconnected.
2)) :LOOGHIDXOWEDFNWRFDPHUDKHDGVHWWLQJVZKHQ
operation control panel is removed.
○
×
SEMI REMOTE MODE
OFF
ON, OFF
21 $OORZV*$,1$:%DQG6+877(56839WREH
set at the camera head when connected to a base
station.
2)) 'LVDEOHVWKHVHIXQFWLRQVDWWKHFDPHUDKHDGZKHQ
connected to a basic station.
○
×
AUTO IRIS SET
―
IRIS SET MODE
OFF
ON, OFF
21 (QDEOHVDXWRLULVRSHUDWLRQVHWWLQJ
* If set to ON, the iris adjustment from the operation control
panel is disabled.
×
×
―
IRIS LEVEL SET
0
WR
$GMXVWVWKHFRQYHUJHQFHOHYHORIDXWRLULV
Shoot the registration chart with the camera and adjust the
value so that the video level becomes 75%.
×
×
―
PEAK RATIO SET
-70
WR
Shoot the gray scale chart with the camera and adjust the
value so that the video level is 100%.
6HWWKHH[SRVXUHIRUDEULJKWDUHDLQWKHGLUHFWLRQDQG
for a dark area in the "-" direction. The default value "50"
indicates no exposure compensation.
×
×
―
IRIS GAIN
50
1 to 100
Sets the auto-iris response sensitivity characteristics.
The auto-iris operation sensitivity is such that "1" is low and
"100" is high.
Hunting tends to occur more often as the value goes up.
(Set it to the default value"50" as long as hunting is not
occurring).
×
×
―
IRIS SPEED
50
1 to 100
Sets the response speed characteristics of the auto-iris.
The auto-iris speed becomes slower for "1" and faster for
"100".
○
×
―
IRIS LIMIT
F22
F22, F20, F18, F16
If the iris is about to close during auto-iris operation, it stops
the iris operation before it completely closes to prevent iris
hunting.
Sets the iris limit value at that time.
○
×
LENS ADJUST
OFF
F16, F2.8, OFF
Sets the output of control voltage for fixed iris value during
lens adjustment. To adjust the relationship between the lens
control voltage value and lens iris value, the control voltage
equivalent of F2.8 and F16 can be output to the lens.
×
×
AWB/ABB MODE
―
AWB WITH A.IRIS
OFF
ON, OFF
6HOHFWZKHWKHU$,5,6LVDXWRPDWLFDOO\LQSXWRUQRWZKHQ
H[HFXWLQJ$:%
* This menu is only valid during self-operation. It is always
OFF during BS/CCU operation.
○
×
―
SMOOTH AWB
ON-0.5s
ON-0.3s, ON-0.5s,
ON-0.7s, ON-1.0s,
ON-1.5s, ON-2.0s,
OFF
6ZLWFKHV$FK%FKRI$:%VPRRWKO\
Transition time of swtching can be set.
○
×
―
AWB REFERENCE
ON
ON, OFF
21 &RQYHUJHVWKH$:%FRQYHUJHQFHYDOXHWR(;7$:%
REF.
2)) 0DNHV5FK%FKFRUUHVSRQGWR*FK
○
×
―
REFERENCE SET
$%%
$%%$:%
&UHDWHVFRQYHUJHQFHYDOXHRI$:%DQG$%%
*3
×
×
AUTO WHITE SHADING
---
6(7ĺ67$57
([HFXWHV$:6$XWR:KLWH6KDGLQJ
0DNHV5FK%FKFRUUHVSRQGWR*FK:KLWH6KDGLQJ<RXPXVW
shoot a uniformly lit white surface.
-
-
Содержание FA-55
Страница 1: ...OFF EXT POWER ACTIVE STANDBY BS CCU HIGH DEFINITION CAMERA SYSTEM HDK 73 FA 55 OPERATION MANUAL ...
Страница 2: ......
Страница 17: ...1 OUTLINE ...
Страница 18: ......
Страница 24: ......
Страница 26: ......
Страница 27: ...2 NAME and FUNCTION ...
Страница 28: ......
Страница 47: ...3 INSTALLATION and CONNECTION ...
Страница 48: ......
Страница 50: ...34 ...
Страница 52: ......
Страница 54: ......
Страница 70: ......
Страница 71: ...4 OPERATION ...
Страница 72: ......
Страница 85: ...5 CAMERA SETTINGS and ADJUSTMENT ...
Страница 86: ......
Страница 121: ...6 TROUBLE SHOOTING and MAINTENANCE ...
Страница 122: ......
Страница 133: ...7 SPECIFICATIONS ...
Страница 134: ......
Страница 137: ...121 i i i 7 7 2 External Dimensions Diagram Right View 337 5 7 2 1 270 5 OFF EXT POWER CTI ST N B BS CCU ...
Страница 138: ...122 i i i Left View 94 3 7 1 337 5 270 5 BREAKER ...
Страница 139: ...123 i i i 7 Front View 138 5 3 94 3 7 1 NS MIC P FUNC ON S M NU OFF CH F PUSH S T ...
Страница 140: ...124 i i i Rear View 138 5 3 INCOM INCOM 1 2 ...
Страница 154: ......
Страница 156: ......
Страница 158: ......
Страница 159: ......