Intended use

///

 

Use

The 

MATRIX DELTA PLUS

 device is used for tempering liquids in closed tubes and closed 

plates in the preparation of samples�

Intended use:

 

Tabletop device

/// Working with the device

  Danger!  

›  Do not use the device in explosive atmospheres, it is not EX-protected� 
›  With substances capable of forming an explosive mixture, appropriate safety measures 

must be applied, e�g� working under a fume hood�

›  To avoid body injury and property damage, observe the relevant safety and accident 

prevention measures when processing hazardous materials�

 

Warning! 

›  Only process samples that will not react dangerously to the extra energy produced through 

processing� This also applies to any extra energy produced in other ways, e�g� through light 
irradiation�

›  Only media whose flash point lies above 170 ºC can be heated with this device (according 

to EN 61010-2-010)�

›  When handling hazardous substances or mixtures of substances which are toxic or 

are contaminated with pathogenic micro-organisms, the user should take appropriate 
precautions� Observe the national regulations, the biosafety level of your laboratory, the 
material safety data sheets�

› For 

germs or biological material or risk goup II or higher, please observe the “Laboratory 

Biosafety Manual” issued by the World Heath Organisation)� 

 

 Caution!

›  Please pay attention to avoiding hand injury when operate the device� 
›  The heating plate and the attachments can be very hot and cause injuries� Be careful when 

touching the attachments�

›  Pay attention to the residual heat after switching off the device� 
› Allow 

the attachments to cool down completely before removing them�

!

 Notice!

›  The device must be operated on flat surface and must not be moved during operation�
›  Covers or parts that can be removed from the device without tools must later be refitted to 

ensure safe operation� This will prevent the infiltration of foreign objects, liquids and other 
contaminants�

›  Never use tubes made of glass or other fragile material� Glass tubes can be smash� 
›  Only use sealed micro test tube and sealed microplate / deepwell plate�
›  The micro test tube / microplate / deepwell plate must always be closed during operation� 

Switch off the device immediately if any material leaks from the vessel� Clean the device 
after disconnected power plug�

›  The feet of the device must be clean and undamaged�

/// Disposal instructions

›  The device, accessories and packaging must be disposed of in accordance with local and 

national regulations�

/// Maintenance

›  The device must only be opened by trained specialists, even during repair� The device must 

be unplugged from the power supply before opening� Live parts inside the device may still 
be live for some time after unplugging from the power supply�

›  Only use original IKA spare parts!

/// Power supply / switching off the device

›  The voltage stated on the type plate must correspond to the power voltage�
›  The device can only be disconnected from the power supply by pulling out the power plug 

or the connector plug�

›  The device must only be operated with the original power cord set�
›  The socket for the power cord must be easily accessible�
›  Socket must be earthed (protective ground contact)�
›  The device will automatically restart in mode B and C following any interruption to the 

power supply�

/// Accessories

›  Protect the device and accessories from bumping and impacting�
›  Check the device and accessories beforehand for damage each time when you use them� 

Do not use damaged components�

›  Safe operation is only guaranteed with the accessories described in the ”Accessories” section�

/// Range of use

Indoor environments similar to that of a laboratory in research, education, commerce or 
industry�

The safety of the user cannot be guaranteed:
›  if the device is operated with accessories that are not supplied or recommended by the 

manufacturer�

›  if the device is operated improperly or contrary to the manufacture’s specifications�
›  if the device or the printed circuit board are modified by third parties�

Содержание MATRIX DELTA PLUS

Страница 1: ...IKA MATRIX DELTA PLUS...

Страница 2: ...2 3 ENGLISH...

Страница 3: ...rning symbols 6 Safety instructions 7 Unpacking 10 Operation 17 Intended use 9 Technical Data 36 Interfaces and outputs 29 Warranty 37 Maintenance and cleaning 34 Accessories 35 Operator panel and dis...

Страница 4: ...p and follow the safety instructions Keep the operating instructions in a place where it can be accessed by everyone Ensure that only trained staff work with the device Follow the safety instructions...

Страница 5: ...n objects liquids and other contaminants Never use tubes made of glass or other fragile material Glass tubes can be smash Only use sealed micro test tube and sealed microplate deepwell plate The micro...

Страница 6: ...nter the timer menu C Programs Prog button Enter the programs menu D Menu button Touch it once main menu is displayed Touch it a second time back to the working screen E Back button Return to the prev...

Страница 7: ...symbol Tempering Indicate the Counter start condition is set to Set temperature reached see Tempering under Timer Tempering heating symbol Indicate the heating function is activated Tempering cooling...

Страница 8: ...14 15 Inserting deepwell plate DWP the microplate MTP Inserting the micro test tubes Attaching the exchangeable attachments Click 3 2 1 2 1 2 1 A B C D E F G H 1 2...

Страница 9: ...ThermoCover cover has been established with the device by pressing down the button the heating function can prevent the formation of condensate Operation Switching on IKA MATRIX Delta Version 1 02 00...

Страница 10: ...IT 100 0 0 00 00 99 59 59 25 0 38 0 max Pausing the tempering function Note During the pause status the tempering function can be switched off by touching tempering button G A IKA MATRIX 2 0 mL Fast S...

Страница 11: ...IKA MATRIX 2 0 mL actual C Set C 38 0 0 00 50 38 0 actual C Fast Fast s s s s s s F F II Locking the buttons Note When the buttons are locked the tempering function still can be deactivated by touchin...

Страница 12: ...l screen Press the Menu button D Select the right menu item by touching the temperature button I Select the left menu item by touching the temperature button H Confirm and enter selected menu item by...

Страница 13: ...you can set Timer Counter for Tempering You can set Timer value from 00 00 01 hh mm ss to 99 59 59 hh mm ss The tempering function stops automatically after the set time has elapsed and the set time a...

Страница 14: ...get values and setting s of segment are valid for the duration indicated in the column Time Afterwards the next program segment is automatically executed Graph X Axis In the X Axis menu you can set 5...

Страница 15: ...through a virtual COM port Note the USB driver is uncessary for Windows 10 system Don t install it for Windows 10 system Setting Languages In the Languages menu option you can select the desired lang...

Страница 16: ...recommendations for the design of electrical plug connections for analogue and digital signal transmission on individual items of laboratory control equipment rev 1 1 The NAMUR commands and the addit...

Страница 17: ...This cable is required to connect RS 232 port to a PC 1 2 RxD 3 TxD 4 5 GND 6 7 RTS 8 CTS 9 1 RxD 2 TxD 3 4 GND 5 6 RTS 7 CTS 8 9 PC 1 2 3 4 5 6 7 8 9 9 8 7 6 5 4 3 2 1 USB 2 0 Cable A micro B This ca...

Страница 18: ...Item and designation of the spare part see www ika com spare parts diagram and spare parts list Software version Briefly visible in the display when the device is switched on Accessories Exchangable a...

Страница 19: ...145 fixed Temperature setting Buttons Temperature setting resolution K 1 0 Temperature display TFT LCD Temperature display resolution K 0 1 Temperature control accuracy K 0 5 Temperature stability K 0...

Страница 20: ...s england ika com MALAYSIA IKA Works Asia Sdn Bhd Phone 60 3 6099 5666 eMail sales lab ika my CHINA IKA Works Guangzhou Phone 86 20 8222 6771 eMail info ika cn POLAND IKA Poland Sp z o o Phone 48 22 2...

Отзывы: