IHP capella 27 Скачать руководство пользователя страница 7

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

7

       

WARNING

 

ALWAYS DISCONNECT POWER 
AND ALLOW THE ELECTRIC 
FIREPLACE TO COOL BEFORE 
PERFORMING ANY CLEANING, 
MAINTENANCE OR RELOCATION 
OF THIS ELECTRIC FIREPLACE.  
TURN CONTROLS TO OFF AND 
REMOVE PLUG FROM OUTLET OR 
TURN OFF CIRCUIT BREAKER TO 
ELECTRIC FIREPLACE.

BACK GLASS

1. The glass is cleaned in the factory during 

assembly. During shipment, installation, 
handling, etc.. The glass surface may col-
lect dust particles.  These can be removed 
by buffi ng lightly with a clean dry cloth.  To 
access the back glass, refer to 

Figure 6

  and 

the removal process in the next section.

2. To remove fi ngerprints or other marks, the 

glass can be cleaned with a damp cloth using 
a good quality household glass cleaner. The 
glass should be completely dried with a lint 
free cloth or paper towel.

3. In the event of glass breakage, vacuum all 

remaining glass pieces with a shop vac.  

DO 

NOT VACUUM WHILE PIECES ARE HOT!  

Replace glass only with replacement parts 
specifi cally for this heater.  Never substitute 
material.  Only fully tempered safety glass 
may be used on this heater.

  b.  Flame Cylinder LED Strip

i.  Remove Mirror panel, following proce-

dure on Page 8 (see 

Brick panel Removal 

Procedure

).

iii. Locate fl ame cylinder drum (see

 Figure 

17

).

 Locate the cotter pin on left side of 

fl ame cylinder and remove it. Remove 
outer plastic sleeve of drum by remov-
ing the (3) screws on the right side of 
the sleeve. Disconnect the left side 
of the fl ame cylinder drum from the 
motor, and slide the outer sleeve off.  
you will have access to the LED strip 
(see 

Figure 18

).

  Note:

 do not exert 

excessive pressure on the drum 
cylinder as this may cause damage.  

v.  Using needle-nose pliers, squeeze the 

plastic clips holding the LED strips in 
place and push them through the holes 
in the LED strip.  Unclip the wires from 
the LED strip and remove it.

6. Reinstall all components that were removed 
(reverse 

Steps 1-5

)

.

  Access LED strips as follows:

 a.   Ember Bed LED Strips- 

i. With the ember bed removed, the 2 

ember bed LED strips will be visible (see 

Figure 13

). 

ii. Using needle-nose pliers, squeeze the 

plastic clips holding the LED strips in 
place and push them through the holes 
in the LED strips (see 

Figure 14

). Unclip 

the wires from the LED strips and remove 
them.  Insert new LED strips and re-
connect the associated wiring.

iii. Plug in power cord or connect power  to 

appliance. Turn on power to test LEDs. 
Disconnect power.

iv. Reverse 

Steps 3 to 5

.

ii.  using a phillips screwdriver, remove the 

fl ame panel (see 

Figure 16

)

.

Figure 12

Mirror Glass Panel

Mirror Glass Panel

Figure 13

LED Strips

LED Strips

Plastic Retaining Clips

Plastic Retaining Clips

Figure 14

Figure 15

M i r r o r e d   G l a s s 

M i r r o r e d   G l a s s 
Retaining Brackets

Retaining Brackets

Grate

Grate

Log/Ember Assembly

Log/Ember Assembly

Figure 16

Figure 17

Figure 18

Flame

Flame
Panel

Panel

Flame Cylinder Drum

Flame Cylinder Drum

LED Strip

Cotter Pin

Cotter Pin

Flame Cylinder 
Cover

(3) Screws

(3) Screws

LED Strip Replacement Procedure:

•  2 LED strips provide illumination for the 
ember bed and 1 LED strip provides illumina-
tion for the fl ame generation assembly.

•  Replacement LED strips are available through 
IHP (see 

Page 16

).

1. Turn off power to the fi replace.
2. Let the fi replace cool, if it has been operat-

ing.

3. (If optional glass panel enclosure is 

installed) Remove glass panel per instruc-
tions provided in kit.

4. Remove the 2 screws on the front of the 

grate (see 

Figure 12

. Also see item #7 on 

Page 17

). Remove Grate.

5. Lift out log/ember assembly by tilting for-

ward and fi rmly pulling on back of ember 
bed assembly. It should pop out from 
track and lift out. Caution: Be careful not 
to scratch the fi nish.

Screws

Screws

Содержание capella 27

Страница 1: ...system and could result in an unsafe and potentially dangerous installation FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APP...

Страница 2: ...lectrical Code latest edition IMPORTANT Beforestartingyourfireplace installation readthisinstallationandopera tion manual very carefully to ensure you understand it completely and in entirety Failure...

Страница 3: ...ER CONTAINER DO NOT RUN ELECTRICAL WIRING OR POWER CORD UNDER CARPETING OR COVER WITH THROW RUGS RUNNERS OR SIMILAR MATERIALS FOR 120 VAC POWER CORD AVOID THE USE OF AN EXTENSION CORD BECAUSE THE EXTE...

Страница 4: ...installation with finish dry wall in place 11 280 mm 32 833 mm 25 635 mm 51 1 4 1302 mm 22 1 2 572 mm Corner View 4 102 mm Electrical Junction Box On Right Side 2 x 4 Electrical Junction Box 31 1 4 79...

Страница 5: ...RNING This appliance is mounted on rubber feet to ensure adequate air circulation beneath fireplace Do not block airflow at the bottom air intakes IMPORTANT Cold climate installation recom mendation w...

Страница 6: ...is a normal occurrence caused by the initial heating of the internal heating elements and should not occur again 4 FlameControlbutton Thisbuttonislocated to the left of the Temperature Button see Figu...

Страница 7: ...eandpushthemthroughtheholes in the LED strip Unclip the wires from the LED strip and remove it 6 Reinstall all components that were removed reverse Steps 1 5 Access LED strips as follows a Ember Bed L...

Страница 8: ...does not work Low batteries Unit switch and or wall switch in on position Homeowner ReplaceAAbatteriesinremotecontrol If problem persists there may have been a loss of power to the unit as a possible...

Страница 9: ...863 1 3 Glass Mirror H3864 1 4a Blower Heating Element and Access Panel Assembly H3865 1 4b Fuse Plate Assembly 5 each H5043 1 5 Flame Cylinder Assembly LED 27 H9121 1 6 Flame Motor H3867 1 7 Log Embe...

Страница 10: ...10 NOTES...

Страница 11: ...Product must be subjected to normal use All precautions and warnings as described in the instruction owner s manual must be followed c damages caused by failing to provide proper maintenance and servi...

Страница 12: ...2015 IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for...

Отзывы: